Rapid, Reliable, and Green: A Novel RP‐HPLC Method for Quercetin Estimation in Green‐Synthesized Nanoparticles

Quercetin (QUE) is a natural flavonoid phyto-constituent found in fruits and vegetables with diverse medicinal properties. Green synthesis nanoparticles using plant extracts have gained attention for their eco-friendly and safe approach. The present work aimed to develop a facile, accurate, and reliable reverse-phase high-performance liquid chromatography (RP-HPLC) technique to determine QUE in nanoparticles. Chromatographic separation was done with a C18 column (4.6 × 250 mm, 5 μm) with a mobile phase of methanol and 0.1% orthophosphoric acid (OPA) (80:20, v/v) with a flow rate of 1.0 mL/min at 371 nm. The method developed for QUE proved to be highly linear in the range of 0.1-8.0 μg/mL (R<sup>2</sup>>0.999) with a retention time of 3.5 min. The limit of detection (LOD) and limit of quantification (LOQ) were 0.6 and 2.1 μg/mL, respectively. Validation parameters such as accuracy, precision, robustness, and specificity were in accordance with ICH guidelines. The novelty of the research work depends on attaining a maximum of QUE at a lower retention time compared to conventional methods.

Authors

Institutions

Publication Details

Journal
Biomedical Chromatography
Published
2025-11-30
DOI
https://doi.org/10.1002/bmc.70280
Primary Topic
Phytochemicals and Antioxidant Activities
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid, Reliable, and Green: A Novel RP‐HPLC Method for Quercetin Estimation in Green‐Synthesized Nanoparticles

Sohan S. Chitlange, Rachana S. Bhimanwar, Chetan Bhoite
Biomedical Chromatography
Phytochemicals and Antioxidant Activities
article

Rapid, Reliable, and Green: A Novel RP‐HPLC Method for Quercetin Estimation in Green‐Synthesized Nanoparticles

Sohan S. Chitlange, Rachana S. Bhimanwar, Chetan Bhoite
article en

Abstract

Quercetin (QUE) is a natural flavonoid phyto-constituent found in fruits and vegetables with diverse medicinal properties. Green synthesis nanoparticles using plant extracts have gained attention for their eco-friendly and safe approach. The present work aimed to develop a facile, accurate, and reliable reverse-phase high-performance liquid chromatography (RP-HPLC) technique to determine QUE in nanoparticles. Chromatographic separation was done with a C18 column (4.6 × 250 mm, 5 μm) with a mobile phase of methanol and 0.1% orthophosphoric acid (OPA) (80:20, v/v) with a flow rate of 1.0 mL/min at 371 nm. The method developed for QUE proved to be highly linear in the range of 0.1-8.0 μg/mL (R<sup>2</sup>>0.999) with a retention time of 3.5 min. The limit of detection (LOD) and limit of quantification (LOQ) were 0.6 and 2.1 μg/mL, respectively. Validation parameters such as accuracy, precision, robustness, and specificity were in accordance with ICH guidelines. The novelty of the research work depends on attaining a maximum of QUE at a lower retention time compared to conventional methods.

Biomedical ChromatographyVol. 40(1)
Delhi Pharmaceutical Science and Research University (IN), Dr. D. Y. Patil Medical College, Hospital and Research Centre (IN), Praj (India) (IN)
Openalex Percentile: Top 62%
Phytochemicals and Antioxidant Activities
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Rapid, Reliable, and Green: A Novel RP‐HPLC Method for Quercetin Estimation in Green‐Synthesized Nanoparticles — Sohan S. Chitlange, Rachana S. Bhimanwar, et al. · Biomedical Chromatography (2025) | TGRS Research Map | TGRS