Circuit Modeling and Simulation of EMI Filter for High Current Power Converters

This paper shows a circuit model that can accurately simulate the differential-mode and common-mode attenuation characteristics of a three-stage EMI filter connected to high-current power converters. Passive components such as common mode choke coils and capacitors are modeled as high-frequency equivalent circuits based on impedance measurement results. For the coils that exhibited characteristics that are difficult to fit manually, vector fitting is used to derive a highly accurate equivalent circuit. The mutual inductance between input and output loops, which has a significant impact on common mode characteristics, is calculated based on the results of electromagnetic field analysis using a 3D CAD model. The combined circuit simulation model is able to predict the filter attenuation characteristics with an accuracy of less than 10dB error for both modes.

Authors

Institutions

Publication Details

Journal
IEEJ Transactions on Fundamentals and Materials
Published
2025-11-30
DOI
https://doi.org/10.1541/ieejfms.145.373
Primary Topic
Electromagnetic Compatibility and Noise Suppression
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Circuit Modeling and Simulation of EMI Filter for High Current Power Converters

Katsuya NOMURA, Kohei Yamagami, Shuhei Chizuwa, Takashi Masuzawa et al.
IEEJ Transactions on Fundamentals and Materials
Electromagnetic Compatibility and Noise Suppression
article

Circuit Modeling and Simulation of EMI Filter for High Current Power Converters

Katsuya NOMURA, Kohei Yamagami, Shuhei Chizuwa, Takashi Masuzawa, T. Manabe
article en

Abstract

This paper shows a circuit model that can accurately simulate the differential-mode and common-mode attenuation characteristics of a three-stage EMI filter connected to high-current power converters. Passive components such as common mode choke coils and capacitors are modeled as high-frequency equivalent circuits based on impedance measurement results. For the coils that exhibited characteristics that are difficult to fit manually, vector fitting is used to derive a highly accurate equivalent circuit. The mutual inductance between input and output loops, which has a significant impact on common mode characteristics, is calculated based on the results of electromagnetic field analysis using a 3D CAD model. The combined circuit simulation model is able to predict the filter attenuation characteristics with an accuracy of less than 10dB error for both modes.

IEEJ Transactions on Fundamentals and MaterialsVol. 145(12)
Mitsubishi Heavy Industries (Germany) (DE), Kwansei Gakuin University (JP)
Openalex Percentile: Top 63%
Electromagnetic Compatibility and Noise Suppression
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.