Elucidating the role of electrolyte velocity homogeneity for scaling up flow fields in vanadium redox flow batteries

The distribution of the electrolyte over the porous electrode is one of the main critical issues that limit the power density of vanadium redox flow batteries. The flow field serves to distribute the electrolyte across the electrode active area, aiming at reducing mass transport overpotentials and pressure drops. This becomes more critical when increasing cell active area. In this work, the performance of a 25 cm 2 interdigitated geometry and two 100 cm 2 interdigitated flow fields characterized by different channels length were firstly compared with polarization curves adopting positive electrolyte at 50 % state of charge. The 100 cm 2 configuration with longer channels exhibited the best performance, with a current density value of 439 mA cm −2 at −0.5 V. Using a 3D computational fluid dynamics model, the performance difference among the three configurations was identified in the mean under-the-rib fluxes and their homogeneity across the electrode area: the Long channels flow field exhibited a heterogeneity index of 19.0 %. Moreover, the analysis of the local pressure drops inside the cell provided further insights into the understanding of the distribution of under-the-rib fluxes. This permitted to design a 100 cm 2 flow field characterized by increased under-the-rib fluxes, evenly distributed throughout the electrode area, characterized by a heterogeneity index of 3.2 %. The developed distributor outperformed the previous ones, reaching 654 mA cm −2 at −0.5 V with an electrolyte flow rate of 1.6 ml min −1 cm −2 . In addition, the new flow field presented a limited pressure drop increase and it demonstrated superior performances even in full-cell configuration. • Flow field of 100 cm 2 with long channels outperforms the one with short channels. • The performance is correlated with the heterogeneity of the under-the-rib fluxes. • Larger ribs and increased channels section lead to homogeneous under-the-rib fluxes. • The developed flow field outperforms the conventional interdigitated ones.

Authors

Institutions

Publication Details

Journal
Chemical Engineering Journal
Published
2025-11-30
DOI
https://doi.org/10.1016/j.cej.2025.171201
Citations
1
Primary Topic
Advanced battery technologies research
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Elucidating the role of electrolyte velocity homogeneity for scaling up flow fields in vanadium redox flow batteries

Francesca Toja, Andrea Casalegno, Matteo Zago, Sara Oriani
1 citations
Chemical Engineering Journal
Advanced battery technologies research
0.73
article

Elucidating the role of electrolyte velocity homogeneity for scaling up flow fields in vanadium redox flow batteries

Francesca Toja, Andrea Casalegno, Matteo Zago, Sara Oriani
article en
1 citations

Abstract

The distribution of the electrolyte over the porous electrode is one of the main critical issues that limit the power density of vanadium redox flow batteries. The flow field serves to distribute the electrolyte across the electrode active area, aiming at reducing mass transport overpotentials and pressure drops. This becomes more critical when increasing cell active area. In this work, the performance of a 25 cm 2 interdigitated geometry and two 100 cm 2 interdigitated flow fields characterized by different channels length were firstly compared with polarization curves adopting positive electrolyte at 50 % state of charge. The 100 cm 2 configuration with longer channels exhibited the best performance, with a current density value of 439 mA cm −2 at −0.5 V. Using a 3D computational fluid dynamics model, the performance difference among the three configurations was identified in the mean under-the-rib fluxes and their homogeneity across the electrode area: the Long channels flow field exhibited a heterogeneity index of 19.0 %. Moreover, the analysis of the local pressure drops inside the cell provided further insights into the understanding of the distribution of under-the-rib fluxes. This permitted to design a 100 cm 2 flow field characterized by increased under-the-rib fluxes, evenly distributed throughout the electrode area, characterized by a heterogeneity index of 3.2 %. The developed distributor outperformed the previous ones, reaching 654 mA cm −2 at −0.5 V with an electrolyte flow rate of 1.6 ml min −1 cm −2 . In addition, the new flow field presented a limited pressure drop increase and it demonstrated superior performances even in full-cell configuration. • Flow field of 100 cm 2 with long channels outperforms the one with short channels. • The performance is correlated with the heterogeneity of the under-the-rib fluxes. • Larger ribs and increased channels section lead to homogeneous under-the-rib fluxes. • The developed flow field outperforms the conventional interdigitated ones.

Chemical Engineering JournalVol. 526
Politecnico di Milano (IT)
Openalex Percentile: Top 21%
Advanced battery technologies research
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.