Comparison of coronavirus disease 19 rapid diagnostic test with gold standard real time reverse transcription polymerase chain reaction in omicron wave of pandemic

Background: The Omicron variant of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) is the most mutated variant identified and contributed to the third wave of the coronavirus disease-19 (COVID-19) pandemic. Due to its high transmissibility, it has replaced the Delta variant, which was the dominant variant during the second wave of the pandemic. Aims and Objectives: This study aims to evaluate whether the highly transmissible, rapidly multiplying, and frequently transforming Omicron variant of SARS-CoV-2 affects the performance of rapid antigen tests (RAT) in the third wave of the COVID-19 pandemic. Materials and Methods: This retrospective study was conducted in a tertiary care hospital in the initial period of the third wave of the COVID-19 pandemic. Socio-demographic information was collectedfrom 480 patients whose nasopharyngeal swabs were received for both RAT and reverse transcription-polymerase chain reaction (RT-PCR) testing. Results: Male preponderance was seen in all patients’ age groups. Substantial agreement between RAT and gold standard RT-PCR was observed. When samples that tested positive by RAT were further analyzed with RT-PCR, most of them showed a cycle threshold value below 25, indicating a higher viral load. Sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio of the COVID-19 RAT were 46.03%, 99.52%, 93.54%, 92.42%, 95.87%, and 0.54%, respectively. Conclusion: The RAT shows high specificity and good agreement with RT-PCR results, making it suitable as a quick point-of-care screening tool, especially in hospitals and areas with high infection rates. TheOmicron variant did not significantly affect the performance of RAT.

Authors

Institutions

Publication Details

Journal
Asian Journal of Medical Sciences
Published
2025-11-30
DOI
https://doi.org/10.71152/ajms.v16i12.4886
Primary Topic
SARS-CoV-2 detection and testing
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of coronavirus disease 19 rapid diagnostic test with gold standard real time reverse transcription polymerase chain reaction in omicron wave of pandemic

Suvarna Joshi, Rashmita Das, Pooja Shah, Soibam Khogen Singh et al.
Asian Journal of Medical Sciences
SARS-CoV-2 detection and testing
article

Comparison of coronavirus disease 19 rapid diagnostic test with gold standard real time reverse transcription polymerase chain reaction in omicron wave of pandemic

Suvarna Joshi, Rashmita Das, Pooja Shah, Soibam Khogen Singh, Mayuri R. Gajbhiye, Rajesh Prabhakar Karykarte
article en

Abstract

Background: The Omicron variant of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) is the most mutated variant identified and contributed to the third wave of the coronavirus disease-19 (COVID-19) pandemic. Due to its high transmissibility, it has replaced the Delta variant, which was the dominant variant during the second wave of the pandemic. Aims and Objectives: This study aims to evaluate whether the highly transmissible, rapidly multiplying, and frequently transforming Omicron variant of SARS-CoV-2 affects the performance of rapid antigen tests (RAT) in the third wave of the COVID-19 pandemic. Materials and Methods: This retrospective study was conducted in a tertiary care hospital in the initial period of the third wave of the COVID-19 pandemic. Socio-demographic information was collectedfrom 480 patients whose nasopharyngeal swabs were received for both RAT and reverse transcription-polymerase chain reaction (RT-PCR) testing. Results: Male preponderance was seen in all patients’ age groups. Substantial agreement between RAT and gold standard RT-PCR was observed. When samples that tested positive by RAT were further analyzed with RT-PCR, most of them showed a cycle threshold value below 25, indicating a higher viral load. Sensitivity, specificity, positive predictive value, negative predictive value, positive likelihood ratio, and negative likelihood ratio of the COVID-19 RAT were 46.03%, 99.52%, 93.54%, 92.42%, 95.87%, and 0.54%, respectively. Conclusion: The RAT shows high specificity and good agreement with RT-PCR results, making it suitable as a quick point-of-care screening tool, especially in hospitals and areas with high infection rates. TheOmicron variant did not significantly affect the performance of RAT.

Asian Journal of Medical SciencesVol. 16(12)
Government Medical College (IN), Johns Hopkins University (US), Kanyakumari Government Medical College (IN)
Openalex Percentile: Top 56%
SARS-CoV-2 detection and testing
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.