Load frequency control in a standalone microgrid: A novel fractional order tilt multilevel PIDF control approach

• A novel FOTMLPIDF controller is proposed to improve the frequency response of autonomous MG. The recommended FOTMLPIDF controller procures the merits of multilevel PID controllers, tilt and fractional order controllers in one controller setup. • QIO algorithm adopted to optimize the FOTMLPIDF controller and supremacy of QIO authenticated over recent optimization techniques. • Efforts have been made to address all the LFC specifications as outlined in literature. The proposed controller has been compared with various controllers from existing studies, including recent controllers such as MLPIDF, TPIDF and PIDF controllers. • Lastly, the robustness of suggested FOTMLPIDF controller is extended to cyber attacks, ESS disconnection, MG uncertainties and renewable intermittencies in a single controller framework. In a standalone microgrid (MG), with intermittent output power from renewable energy sources, communication delays, low system inertia, parametric uncertainties, and load changes cause power imbalances in the MG. The uncontrolled power imbalances can lead to significant frequency deviations and thereby a blackout. PID controllers usually address these problems, but they may not completely resolve the dynamic requirements of modern MG. This paper proposes a novel fractional order tilt multilevel PID controller with filter (FOTMLPIDF) to enhance the frequency response of the MG. In this method, the proposed approach coordinates diesel engine generators (DEGs) and fuel cells (FCs) to manage the MG frequency effectively. The proposed controller parameters are optimized effectively through the use of a recently developed Quadratic Interpolation Optimization (QIO) algorithm. Various disturbance scenarios are accounted for to assess the performance of the suggested controller. The simulation results substantiate that the recommended controller attains improved dynamics compared to advanced controllers in the literature, including MLPIDF, TPIDF, and PIDF controllers. Up to 50% of renewable penetration, the overall frequency error is reduced by 60%, 87% and 95% respectively. Besides that, the suggested controller is more robust to parametric variations and cyber attacks.

Authors

Institutions

Publication Details

Journal
Franklin Open
Published
2025-11-29
DOI
https://doi.org/10.1016/j.fraope.2025.100451
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Load frequency control in a standalone microgrid: A novel fractional order tilt multilevel PIDF control approach

Anil Annamraju
Franklin Open
Frequency Control in Power Systems
article

Load frequency control in a standalone microgrid: A novel fractional order tilt multilevel PIDF control approach

Anil Annamraju
article en

Abstract

• A novel FOTMLPIDF controller is proposed to improve the frequency response of autonomous MG. The recommended FOTMLPIDF controller procures the merits of multilevel PID controllers, tilt and fractional order controllers in one controller setup. • QIO algorithm adopted to optimize the FOTMLPIDF controller and supremacy of QIO authenticated over recent optimization techniques. • Efforts have been made to address all the LFC specifications as outlined in literature. The proposed controller has been compared with various controllers from existing studies, including recent controllers such as MLPIDF, TPIDF and PIDF controllers. • Lastly, the robustness of suggested FOTMLPIDF controller is extended to cyber attacks, ESS disconnection, MG uncertainties and renewable intermittencies in a single controller framework. In a standalone microgrid (MG), with intermittent output power from renewable energy sources, communication delays, low system inertia, parametric uncertainties, and load changes cause power imbalances in the MG. The uncontrolled power imbalances can lead to significant frequency deviations and thereby a blackout. PID controllers usually address these problems, but they may not completely resolve the dynamic requirements of modern MG. This paper proposes a novel fractional order tilt multilevel PID controller with filter (FOTMLPIDF) to enhance the frequency response of the MG. In this method, the proposed approach coordinates diesel engine generators (DEGs) and fuel cells (FCs) to manage the MG frequency effectively. The proposed controller parameters are optimized effectively through the use of a recently developed Quadratic Interpolation Optimization (QIO) algorithm. Various disturbance scenarios are accounted for to assess the performance of the suggested controller. The simulation results substantiate that the recommended controller attains improved dynamics compared to advanced controllers in the literature, including MLPIDF, TPIDF, and PIDF controllers. Up to 50% of renewable penetration, the overall frequency error is reduced by 60%, 87% and 95% respectively. Besides that, the suggested controller is more robust to parametric variations and cyber attacks.

Franklin OpenVol. 14
Vignana Jyothi Institute of Management (IN)
Openalex Percentile: Top 63%
Frequency Control in Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.