Filtering-Based Preconditioner for Accelerated High-Dimensional Cone-Beam CT Image Reconstruction

Abstract Model-based image reconstruction algorithms are known to produce high-accuracy images but are still rarely used in cone-beam computed tomography. One of the reasons for this is the computational requirements of model-based iterative algorithms, as it can take hundreds of iterations to obtain converged images. In this work, we present a measurement space-based preconditioner applied to the primal-dual hybrid gradient (PDHG) algorithm. The method is compared with the regular PDHG, FISTA, and OS-SART algorithms, as well as to a PDHG algorithm where the step-size parameters are adaptively computed. All tested algorithms utilize subsets for acceleration. The presented filtering-based preconditioner can obtain convergence in 10 iterations with 20 subsets, compared to a hundred or more iterations required by the other tested methods. The presented method is also computationally fast and has only a 15% increase in computation time per iteration compared to PDHG without the preconditioner.

Authors

Institutions

Publication Details

Journal
Journal of Mathematical Imaging and Vision
Published
2025-11-29
DOI
https://doi.org/10.1007/s10851-025-01276-4
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Filtering-Based Preconditioner for Accelerated High-Dimensional Cone-Beam CT Image Reconstruction

Ville Kolehmainen, Ari Hietanen, Marko Vauhkonen, Kati Niinimäki et al.
Journal of Mathematical Imaging and Vision
Medical Imaging Techniques and Applications
article

Filtering-Based Preconditioner for Accelerated High-Dimensional Cone-Beam CT Image Reconstruction

Ville Kolehmainen, Ari Hietanen, Marko Vauhkonen, Kati Niinimäki, Ville-Veikko Wettenhovi
article en

Abstract

Abstract Model-based image reconstruction algorithms are known to produce high-accuracy images but are still rarely used in cone-beam computed tomography. One of the reasons for this is the computational requirements of model-based iterative algorithms, as it can take hundreds of iterations to obtain converged images. In this work, we present a measurement space-based preconditioner applied to the primal-dual hybrid gradient (PDHG) algorithm. The method is compared with the regular PDHG, FISTA, and OS-SART algorithms, as well as to a PDHG algorithm where the step-size parameters are adaptively computed. All tested algorithms utilize subsets for acceleration. The presented filtering-based preconditioner can obtain convergence in 10 iterations with 20 subsets, compared to a hundred or more iterations required by the other tested methods. The presented method is also computationally fast and has only a 15% increase in computation time per iteration compared to PDHG without the preconditioner.

Journal of Mathematical Imaging and VisionVol. 67(6)
University of Eastern Finland (FI), Planmeca (Finland) (FI)
China Scholarship Council, Jenny ja Antti Wihurin Rahasto
Openalex Percentile: Top 48%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.