Continuous autonomic system monitoring during neurosurgical procedures –proof of concept

Vegetative reactions are common during neurosurgical procedures. Known effects are mainly cardiovascular, including tachy- and bradyarrhythmia, hyper- and hypotonia as well as cardiac arrest. Computer-assisted real-time analysis of heart rate variability (HRV), baroreflex-sensitivity (BRS) allows for continuous evaluation of the autonomic nervous system (ANS). We analyzed ANS parameters during intracranial neurosurgical procedures. In this pilot study, we aim to provide proof-of-concept that ANS monitoring during surgery is feasible and yields stable results.We included 129 consecutive patients undergoing neurosurgery for intracranial pathologies over a period of four months. Heart rate (HR) and mean arterial pressure (MAP) were continuously monitored during routine anesthesiology care. Data were recorded via ICM + software. HRV, BRS and other vegetative parameters were calculated continuously. Intraoperative events such as hypo-/hypertonia or brady-/tachycardia were monitored.Mean age was 47.2 ± 17.7 years. Of all patients, 54.3% were male (n = 70). For every patient, four intraoperative episodes were defined: start of anesthesia until incision - start of incision until craniotomy - craniotomy until end of resection or intracranial manipulation - end phase until skin closure. BRS continuously decreased during cranial surgery, indicating stabilized autonomic function. Furthermore, blood pressure variability was increased during semi-sitting surgery.Autonomic system monitoring during neurosurgical procedures is safe and feasible. Intraoperatively, an increasing sympathetic activity has been observed without clear disctinction between surgical or anesthesiological events as underlying cause. Monitoring results are reproducible and may be of importance for the detection and prevention of intraoperative cardiovascular events.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Monitoring and Computing
Published
2025-11-29
DOI
https://doi.org/10.1007/s10877-025-01386-9
Primary Topic
Anesthesia and Sedative Agents
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Continuous autonomic system monitoring during neurosurgical procedures –proof of concept

Martin U. Schuhmann, Dimitar Stoyanov, Julian Zipfel, Berthold Drexler et al.
Journal of Clinical Monitoring and Computing
Anesthesia and Sedative Agents
article

Continuous autonomic system monitoring during neurosurgical procedures –proof of concept

Martin U. Schuhmann, Dimitar Stoyanov, Julian Zipfel, Berthold Drexler, Marek Czosnyka
article en

Abstract

Vegetative reactions are common during neurosurgical procedures. Known effects are mainly cardiovascular, including tachy- and bradyarrhythmia, hyper- and hypotonia as well as cardiac arrest. Computer-assisted real-time analysis of heart rate variability (HRV), baroreflex-sensitivity (BRS) allows for continuous evaluation of the autonomic nervous system (ANS). We analyzed ANS parameters during intracranial neurosurgical procedures. In this pilot study, we aim to provide proof-of-concept that ANS monitoring during surgery is feasible and yields stable results.We included 129 consecutive patients undergoing neurosurgery for intracranial pathologies over a period of four months. Heart rate (HR) and mean arterial pressure (MAP) were continuously monitored during routine anesthesiology care. Data were recorded via ICM + software. HRV, BRS and other vegetative parameters were calculated continuously. Intraoperative events such as hypo-/hypertonia or brady-/tachycardia were monitored.Mean age was 47.2 ± 17.7 years. Of all patients, 54.3% were male (n = 70). For every patient, four intraoperative episodes were defined: start of anesthesia until incision - start of incision until craniotomy - craniotomy until end of resection or intracranial manipulation - end phase until skin closure. BRS continuously decreased during cranial surgery, indicating stabilized autonomic function. Furthermore, blood pressure variability was increased during semi-sitting surgery.Autonomic system monitoring during neurosurgical procedures is safe and feasible. Intraoperatively, an increasing sympathetic activity has been observed without clear disctinction between surgical or anesthesiological events as underlying cause. Monitoring results are reproducible and may be of importance for the detection and prevention of intraoperative cardiovascular events.

Journal of Clinical Monitoring and Computing
University of Cambridge (GB), University Children's Hospital Tübingen (DE), STZ eyetrial (DE), Addenbrooke's Hospital (GB), University of Tübingen (DE)
Openalex Percentile: Top 44%
Anesthesia and Sedative Agents
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.