A Bioinspired Force‐Inducible Hydrogel Conduit for Peripheral Nerve Regeneration

Long-gap peripheral nerve injury (PNI) presents a significant challenge since the growth cone at the proximal end fails to detect and respond to neurotrophic signals from the distal ends, even when bridging the long-gap with nerve guide conduits (NGCs), impeding the motivated growth of new axons. In this study, a bioinspired force-inducible multichannel nerve guide conduit (FI-MNGC) is developed, constructed from silk fibrin-based hydrogel. By mimicking the gradient capillary architectures in vascular plants, the FI-MNGC utilizes a multichannel design with gradient apertures that can self-generate enhanced capillary forces, which not only promote directed axon growth but also guide the directed delivery of Schwann cells (SCs) toward the distal ends of the injured nerve, without the need for any external stimuli. Implemented in a rat model with a 16 mm and a rabbit model with a 30 mm long-gap sciatic nerve defect, the FI-MNGC significantly accelerates the recovery process, paralleling the efficacy of autografts in nerve regeneration, functional recovery, and repair speed. This innovative approach offers a promising alternative to autografts, enhancing the potential for clinical implementation in long-gap PNI therapies.

Authors

Institutions

Publication Details

Journal
Advanced Materials
Published
2025-11-28
DOI
https://doi.org/10.1002/adma.202516449
Citations
2
Primary Topic
Nerve injury and regeneration
Type
article
Field-Weighted Citation Impact
1.82

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Bioinspired Force‐Inducible Hydrogel Conduit for Peripheral Nerve Regeneration

Wei Zhao, Feng Xu, Xueyong Xie, Dongwei Lan et al.
2 citations
Advanced Materials
Nerve injury and regeneration
1.82
article

A Bioinspired Force‐Inducible Hydrogel Conduit for Peripheral Nerve Regeneration

Wei Zhao, Feng Xu, Xueyong Xie, Dongwei Lan, Lan Chen, Haoyu Wang, Bo Deng, Xueliang Liu, Yizhou Xie, Meng Lei
article en
2 citations

Abstract

Long-gap peripheral nerve injury (PNI) presents a significant challenge since the growth cone at the proximal end fails to detect and respond to neurotrophic signals from the distal ends, even when bridging the long-gap with nerve guide conduits (NGCs), impeding the motivated growth of new axons. In this study, a bioinspired force-inducible multichannel nerve guide conduit (FI-MNGC) is developed, constructed from silk fibrin-based hydrogel. By mimicking the gradient capillary architectures in vascular plants, the FI-MNGC utilizes a multichannel design with gradient apertures that can self-generate enhanced capillary forces, which not only promote directed axon growth but also guide the directed delivery of Schwann cells (SCs) toward the distal ends of the injured nerve, without the need for any external stimuli. Implemented in a rat model with a 16 mm and a rabbit model with a 30 mm long-gap sciatic nerve defect, the FI-MNGC significantly accelerates the recovery process, paralleling the efficacy of autografts in nerve regeneration, functional recovery, and repair speed. This innovative approach offers a promising alternative to autografts, enhancing the potential for clinical implementation in long-gap PNI therapies.

Advanced MaterialsVol. 38(8)
Xi'an Jiaotong University (CN)
National Natural Science Foundation of China, Key Research and Development Projects of Shaanxi Province
Openalex Percentile: Top 13%
Nerve injury and regeneration
1.82
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.