Slope-Baseline-Suppressed and Wavelength-Precise Scanning Off-Axis Integrated Cavity Output Spectroscopy with Active Locking for <sup>13</sup> CO <sub>2</sub> / <sup>12</sup> CO <sub>2</sub> Isotope Measurement

Conventional off-axis integrated cavity output spectroscopy (OA-ICOS) measurements suffer from a tilted baseline in the <i>Y</i>-axis direction and nonlinear wavelength variations across the <i>X</i>-axis, both of which degrade measurement accuracy. Here, we present an improved OA-ICOS variant, featuring ramp-baseline immunity and wavelength-precise scanning capabilities, realized through active locking technology. A custom-designed wavelength meter with simple construction and rapid response was designed to enable precise wavelength measurement and feedback locking. Simultaneously, laser power amplification combined with feedback control ensures wavelength-independent uniform optical power. This approach delivers three significant advantages. First, the amplified probe light mitigates the throughput constraint in off-axis configurations and partially eases the demands on the photodetector for weak signal detection and amplification. Second, the flat spectral baseline reduces estimation errors associated with nonlinear ramp backgrounds while simultaneously simplifying signal processing and improving measurement accuracy. Finally, active wavelength locking delivers accurate wavelength acquisition, enabling precise spectral characterization. Using an off-axis configured optical cavity, as well as a near-infrared diode laser, the feasibility and practical efficacy of this active stabilization approach is experimentally validated by recording the spectra of <sup>12</sup>CO<sub>2</sub> and <sup>13</sup>CO<sub>2</sub> isotopologues in the laboratory and in the field.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-11-28
DOI
https://doi.org/10.1021/acs.analchem.5c04382
Primary Topic
Spectroscopy and Laser Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Slope-Baseline-Suppressed and Wavelength-Precise Scanning Off-Axis Integrated Cavity Output Spectroscopy with Active Locking for 13 CO 2 / 12 CO 2 Isotope Measurement

Guishi Wang, Kun Liu, Ligang Shao, Shiling Feng et al.
Analytical Chemistry
Spectroscopy and Laser Applications
article

Slope-Baseline-Suppressed and Wavelength-Precise Scanning Off-Axis Integrated Cavity Output Spectroscopy with Active Locking for 13 CO 2 / 12 CO 2 Isotope Measurement

Guishi Wang, Kun Liu, Ligang Shao, Shiling Feng, Tao Cheng, Ruifeng Wang, Xiaoming Gao, Xinqian Guo, Jia‐Jin Jason Chen, Jiaoxu Mei
article en

Abstract

Conventional off-axis integrated cavity output spectroscopy (OA-ICOS) measurements suffer from a tilted baseline in the <i>Y</i>-axis direction and nonlinear wavelength variations across the <i>X</i>-axis, both of which degrade measurement accuracy. Here, we present an improved OA-ICOS variant, featuring ramp-baseline immunity and wavelength-precise scanning capabilities, realized through active locking technology. A custom-designed wavelength meter with simple construction and rapid response was designed to enable precise wavelength measurement and feedback locking. Simultaneously, laser power amplification combined with feedback control ensures wavelength-independent uniform optical power. This approach delivers three significant advantages. First, the amplified probe light mitigates the throughput constraint in off-axis configurations and partially eases the demands on the photodetector for weak signal detection and amplification. Second, the flat spectral baseline reduces estimation errors associated with nonlinear ramp backgrounds while simultaneously simplifying signal processing and improving measurement accuracy. Finally, active wavelength locking delivers accurate wavelength acquisition, enabling precise spectral characterization. Using an off-axis configured optical cavity, as well as a near-infrared diode laser, the feasibility and practical efficacy of this active stabilization approach is experimentally validated by recording the spectra of <sup>12</sup>CO<sub>2</sub> and <sup>13</sup>CO<sub>2</sub> isotopologues in the laboratory and in the field.

Analytical ChemistryVol. 97(50)
University of Science and Technology of China (CN), Chinese Academy of Sciences (CN), Hefei Institutes of Physical Science (CN), Anhui Institute of Optics and Fine Mechanics (CN), Interaction Design (United Kingdom) (GB)
Openalex Percentile: Top 66%
Spectroscopy and Laser Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.