VHEE-SSB grid: spot-scanning beam enabled spatially fractionated and FLASH radiotherapy with very high energy electron beams

<i>Objectives.</i>This study aims to demonstrate the feasibility of combining spatially fractionated radiotherapy (SFRT) and FLASH radiotherapy (FLASH-RT) techniques using very high energy electron (VHEE) through Monte Carlo simulations and to develop a simulation platform for this purpose.<i>Approach.</i>The simulation platform was built in TOPAS based on the beam parameters of the Wuhan Advanced Light Source (WALS) linear accelerator. Quadrupole magnets are used to focus VHEE beams to control the longitudinal depth of the maximum dose. Lateral scanning irradiation is achieved by combining deflecting magnets. The spread-out electron peak (SOEP) depth adjustment, and spot scanning were achieved through magnetic field adjustments. The dose distribution of VHEE in the water phantom was simulated, and the three-dimensional dose distribution, dose volume histogram (DVH), and peak-to-valley ratio were analyzed.<i>Main results.</i>Based on the fitted relationships, Monte Carlo simulations with 10<sup>6</sup>particles were conducted in TOPAS to verify the positions of maximum dose, yielding millimeter errors. The SOEP flatness between 12-17 cm depths exceeded 98.7%. SFRT simulated at four target points showed a peak-to-valley dose ratio (D<sub>10%</sub>/D<sub>90%</sub>) of 11.026, where D<sub>10%</sub>is the minimum dose within the highest 10% dose voxels, and D<sub>90%</sub>is the minimum dose received by 90% of the target volume. A volume fraction of 4.41% within the PTV received ⩾90% of the maximum dose. The dose rate in the PTV reached up to 54.25 Gy s<sup>-1</sup>under 200 nA electron beam irradiation.<i>Significance.</i>Take the example of beam parameters of the linear accelerator at WALS, the simulation platform is validated for conducting research on combined SFRT and FLASH-RT for deep tumor radiation treatment. This also demonstrates the feasibility of combining SFRT and FLASH-RT using VHEE.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-11-28
DOI
https://doi.org/10.1088/1361-6560/ae25b1
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

VHEE-SSB grid: spot-scanning beam enabled spatially fractionated and FLASH radiotherapy with very high energy electron beams

Hui Liu, Zeyi Dai, Zhitao Dai, Dazhen Jiang et al.
Physics in Medicine and Biology
Advanced Radiotherapy Techniques
article

VHEE-SSB grid: spot-scanning beam enabled spatially fractionated and FLASH radiotherapy with very high energy electron beams

Hui Liu, Zeyi Dai, Zhitao Dai, Dazhen Jiang, Yuancun Nie, Jia Li, Yajun Jia, X. J. Tan, Chaofan An
article en

Abstract

<i>Objectives.</i>This study aims to demonstrate the feasibility of combining spatially fractionated radiotherapy (SFRT) and FLASH radiotherapy (FLASH-RT) techniques using very high energy electron (VHEE) through Monte Carlo simulations and to develop a simulation platform for this purpose.<i>Approach.</i>The simulation platform was built in TOPAS based on the beam parameters of the Wuhan Advanced Light Source (WALS) linear accelerator. Quadrupole magnets are used to focus VHEE beams to control the longitudinal depth of the maximum dose. Lateral scanning irradiation is achieved by combining deflecting magnets. The spread-out electron peak (SOEP) depth adjustment, and spot scanning were achieved through magnetic field adjustments. The dose distribution of VHEE in the water phantom was simulated, and the three-dimensional dose distribution, dose volume histogram (DVH), and peak-to-valley ratio were analyzed.<i>Main results.</i>Based on the fitted relationships, Monte Carlo simulations with 10<sup>6</sup>particles were conducted in TOPAS to verify the positions of maximum dose, yielding millimeter errors. The SOEP flatness between 12-17 cm depths exceeded 98.7%. SFRT simulated at four target points showed a peak-to-valley dose ratio (D<sub>10%</sub>/D<sub>90%</sub>) of 11.026, where D<sub>10%</sub>is the minimum dose within the highest 10% dose voxels, and D<sub>90%</sub>is the minimum dose received by 90% of the target volume. A volume fraction of 4.41% within the PTV received ⩾90% of the maximum dose. The dose rate in the PTV reached up to 54.25 Gy s<sup>-1</sup>under 200 nA electron beam irradiation.<i>Significance.</i>Take the example of beam parameters of the linear accelerator at WALS, the simulation platform is validated for conducting research on combined SFRT and FLASH-RT for deep tumor radiation treatment. This also demonstrates the feasibility of combining SFRT and FLASH-RT using VHEE.

Physics in Medicine and BiologyVol. 70(24)
Chinese Academy of Medical Sciences & Peking Union Medical College (CN), Peking Union Medical College Hospital (CN), Wuhan University (CN), Zhongnan Hospital of Wuhan University (CN), Hubei University (CN)
Openalex Percentile: Top 54%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.