High Voltage Modulator for the TCV Diagnostic Neutral Beam Injector
A Diagnostic Neutral Beam Injector (DNBI) is operated on the TCV Tokamak since 2000. Over the years, the plasma source and the ion optical system have benefited from several upgrades, whereas the power supply system remained almost unchanged. DNBI operation is now compromised by the obsolescence of both the power components and the control infrastructure. To allow for a long term reliable operation, a complete renew of the power supplies set is ongoing. It includes a high-speed current source rated <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$500 ~\mathrm{A} / 100 ~\mathrm{V} / 2 ~\mathrm{s}$</tex> for the arc-discharge plasma source (presented separately) and a High Voltage Modulator (HVM) rated <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$55 \text{kV} / 5 ~\mathrm{A} / 2 ~\mathrm{s}$</tex>.
Authors
- D. Fasel (ORCID: https://orcid.org/0000-0002-4702-7476)
- Luiz Carlos Moreira (ORCID: https://orcid.org/0000-0001-6829-5317)
- J. Orsinger
- A. Listopad (ORCID: https://orcid.org/0000-0002-7359-1185)
- D. Velasco de la Fuente
- U. Siravo (ORCID: https://orcid.org/0009-0001-6247-9999)
- J. Dubray
- S. Delaley
- A. Karpuchov
Institutions
- Sirtex (Germany) (DE)
- École Polytechnique Fédérale de Lausanne (CH)
Publication Details
- Published
- 2025-06-15
- DOI
- https://doi.org/10.1109/ppps56198.2025.11248295
- Primary Topic
- Magnetic confinement fusion research
- Type
- article
- Field-Weighted Citation Impact
- 0.00