Iron(III) modified glassy carbon electrode for adsorption stripping voltammetric detection of uric acid

A ferric-doped zeolite-modified electrode was fabricated for the determination of uric acid. The ferric-doped zeolite was responsible for the electrocatalytic oxidation of uric acid in a buffer solution (pH 4.6). The analytical performance of the ferric-doped zeolite modified electrode was evaluated using adsorption stripping square wave voltammetry. A linear anodic response for uric acid in the concentration range 0.6 – 60.0 µM, a detection limit of 0.23 µM, and a sensitivity of 0.64 µA/µM were obtained. Finally, the proposed method was used for the determination of uric acid in a urine sample, and hence it has potential application for clinical samples. KEY WORDS: Iron(III) modified electrode, Zeolite, Uric acid, Adsorption stripping square wave voltammetry Bull. Chem. Soc. Ethiop. 2025, 39(12), 2549-2557 DOI: https://dx.doi.org/10.4314/bcse.v39i12.14

Authors

Publication Details

Journal
Bulletin of the Chemical Society of Ethiopia
Published
2025-11-27
DOI
https://doi.org/10.4314/bcse.v39i12.14
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Iron(III) modified glassy carbon electrode for adsorption stripping voltammetric detection of uric acid

Isabel Dı́az, Merid Tessema, Theodros Solomon, Solomon Mehretie et al.
Bulletin of the Chemical Society of Ethiopia
Electrochemical sensors and biosensors
article

Iron(III) modified glassy carbon electrode for adsorption stripping voltammetric detection of uric acid

Isabel Dı́az, Merid Tessema, Theodros Solomon, Solomon Mehretie, Shimelis Admassie, José Losada
article en

Abstract

A ferric-doped zeolite-modified electrode was fabricated for the determination of uric acid. The ferric-doped zeolite was responsible for the electrocatalytic oxidation of uric acid in a buffer solution (pH 4.6). The analytical performance of the ferric-doped zeolite modified electrode was evaluated using adsorption stripping square wave voltammetry. A linear anodic response for uric acid in the concentration range 0.6 – 60.0 µM, a detection limit of 0.23 µM, and a sensitivity of 0.64 µA/µM were obtained. Finally, the proposed method was used for the determination of uric acid in a urine sample, and hence it has potential application for clinical samples. KEY WORDS: Iron(III) modified electrode, Zeolite, Uric acid, Adsorption stripping square wave voltammetry Bull. Chem. Soc. Ethiop. 2025, 39(12), 2549-2557 DOI: https://dx.doi.org/10.4314/bcse.v39i12.14

Bulletin of the Chemical Society of EthiopiaVol. 39(12)
Uppsala Universitet, Agencia Estatal de Investigación
Openalex Percentile: Top 63%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.