Building-related symptoms in school environment: Predictability using machine learning approach

Building-related symptoms (BRS) are commonly experienced by students in schools and are potentially affecting academic performance and health. Even though indoor environment quality (IEQ) measurements indicated fair conditions, students still perceived discomfort that led to symptoms, highlighting the necessity of collecting user-feedback about IEQ-complaints. This study aimed to predict and understand the prevalence of BRS ( headache, tiredness, cough, dry eyes-hands ) experienced by students in classrooms using machine-learning (ML) approach based on measurement data, building factors, and prevalence of IEQ-complaints. We collected measurement data (from indoor and outdoor climate), building factors, and user-feedback by students via online-platform across three sampled classrooms each campaign during three consecutive school semesters. Significant input variables for ML were pre-selected using statistical tests. ML models were evaluated based on accuracy metrics and SHAP analysis for input interpretation. Models using measurement data alone performed poorly (testing R² <50%) to predict prevalence of BRS, whereas adding building factors and prevalence of IEQ-complaints increased accuracy (R² up to 95%) of prediction of BRS with lower RMSE. In addition, interpretation from SHAP analysis showed IEQ-complaints especially related with indoor air quality (e.g., heavy air , dust & dirt , and dry air ) as significant contributors for predicting prevalence of BRS. We conclude that the framework of combining objective measurements with occupant-reported complaints can be reliable, interpretable predictions of symptom prevalence. This study is limited by single-school setting, health confounders, and symptoms verification. Future research may contribute to exploring wider set of input variables, applicability, and variation of complaints preference. • Predicting prevalence of BRS is less accurate (R 2 <50%) solely on indoor data • IEQ-complaints and building factors improved ML predictions (R 2 up to 90%) • User-feedback system reinforces the need for participatory monitoring system

Authors

Institutions

Publication Details

Journal
Indoor Environments
Published
2025-11-28
DOI
https://doi.org/10.1016/j.indenv.2025.100140
Primary Topic
Indoor Air Quality and Microbial Exposure
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Building-related symptoms in school environment: Predictability using machine learning approach

Britt Ann Kåstad Høiskar, Jivitesh Sharma, Mirjam F. Fredriksen, Guangyu Cao et al.
Indoor Environments
Indoor Air Quality and Microbial Exposure
article

Building-related symptoms in school environment: Predictability using machine learning approach

Britt Ann Kåstad Høiskar, Jivitesh Sharma, Mirjam F. Fredriksen, Guangyu Cao, A. Alam, Hans Martin Mathisen, Alena Bartoňová, Zhirong Yang, Dinastry Pramadita Zakiudin, Tore Fredriksen, Kai Gustavsen
article en

Abstract

Building-related symptoms (BRS) are commonly experienced by students in schools and are potentially affecting academic performance and health. Even though indoor environment quality (IEQ) measurements indicated fair conditions, students still perceived discomfort that led to symptoms, highlighting the necessity of collecting user-feedback about IEQ-complaints. This study aimed to predict and understand the prevalence of BRS ( headache, tiredness, cough, dry eyes-hands ) experienced by students in classrooms using machine-learning (ML) approach based on measurement data, building factors, and prevalence of IEQ-complaints. We collected measurement data (from indoor and outdoor climate), building factors, and user-feedback by students via online-platform across three sampled classrooms each campaign during three consecutive school semesters. Significant input variables for ML were pre-selected using statistical tests. ML models were evaluated based on accuracy metrics and SHAP analysis for input interpretation. Models using measurement data alone performed poorly (testing R² <50%) to predict prevalence of BRS, whereas adding building factors and prevalence of IEQ-complaints increased accuracy (R² up to 95%) of prediction of BRS with lower RMSE. In addition, interpretation from SHAP analysis showed IEQ-complaints especially related with indoor air quality (e.g., heavy air , dust & dirt , and dry air ) as significant contributors for predicting prevalence of BRS. We conclude that the framework of combining objective measurements with occupant-reported complaints can be reliable, interpretable predictions of symptom prevalence. This study is limited by single-school setting, health confounders, and symptoms verification. Future research may contribute to exploring wider set of input variables, applicability, and variation of complaints preference. • Predicting prevalence of BRS is less accurate (R 2 <50%) solely on indoor data • IEQ-complaints and building factors improved ML predictions (R 2 up to 90%) • User-feedback system reinforces the need for participatory monitoring system

Indoor EnvironmentsVol. 2(4)
Norwegian University of Science and Technology (NO), Kjeller Innovasjon (Norway) (NO), Norwegian Golf Federation (NO), Asthma Association (BG)
Openalex Percentile: Top 54%
Indoor Air Quality and Microbial Exposure
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.