Validity and Reliability of an On‐Bike Sensor System for the Determination of Aerodynamic Drag in Cycling

Cycling performance is strongly influenced by aerodynamics, with most resistive drag forces being attributed to the rider. The Body Rocket device (BR) is an on-bike sensor system that uses the same load cell technology as a wind tunnel, directly measuring real-time aerodynamic resistance (CdA) from the rider. This study aimed to measure the validity and reliability of CdA measures from BR in two experiments. In Experiment 1, validity of BR was assessed in wind tunnel with a rod and discs of known diameter attached to the end change CdA by a known amount. Experiment 2, examined the validity and reliability of BR in a 250m indoor velodrome. Ten cyclists performed 7 identical efforts at ∼40 km/h for 10 laps of the velodrome, the first 4 to assess validity with the same rod and discs used in the wind tunnel, with the remaining 3 without changes in resistance or the riders changing position to assess reliability. Validity results demonstrated BR measured CdA to be strongly correlated with calculated CdA from the disc addition (r = 0.99), with the smallest identified changes being 0.002 m<sup>2</sup> across wind tunnel and velodrome. Good agreement was found between theoretical and measured CdA with varying disc sizes (95% limits of agreement = -0.012 to 0.009 m<sup>2</sup>). A high level of reliability was demonstrated during Experiment 2 with strong intraclass correlation (0.99) and small coefficient of variation (1.67%). Findings of this study demonstrate BR is a valid and reliable device for measuring real-time CdA during cycling in an indoor velodrome.

Authors

Institutions

Publication Details

Journal
European Journal of Sport Science
Published
2025-11-28
DOI
https://doi.org/10.1002/ejsc.70098
Primary Topic
Sports Performance and Training
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validity and Reliability of an On‐Bike Sensor System for the Determination of Aerodynamic Drag in Cycling

Stuart Gibson, Christopher R. J. Fennell, James Hopker, Callum Barnes
European Journal of Sport Science
Sports Performance and Training
article

Validity and Reliability of an On‐Bike Sensor System for the Determination of Aerodynamic Drag in Cycling

Stuart Gibson, Christopher R. J. Fennell, James Hopker, Callum Barnes
article en

Abstract

Cycling performance is strongly influenced by aerodynamics, with most resistive drag forces being attributed to the rider. The Body Rocket device (BR) is an on-bike sensor system that uses the same load cell technology as a wind tunnel, directly measuring real-time aerodynamic resistance (CdA) from the rider. This study aimed to measure the validity and reliability of CdA measures from BR in two experiments. In Experiment 1, validity of BR was assessed in wind tunnel with a rod and discs of known diameter attached to the end change CdA by a known amount. Experiment 2, examined the validity and reliability of BR in a 250m indoor velodrome. Ten cyclists performed 7 identical efforts at ∼40 km/h for 10 laps of the velodrome, the first 4 to assess validity with the same rod and discs used in the wind tunnel, with the remaining 3 without changes in resistance or the riders changing position to assess reliability. Validity results demonstrated BR measured CdA to be strongly correlated with calculated CdA from the disc addition (r = 0.99), with the smallest identified changes being 0.002 m<sup>2</sup> across wind tunnel and velodrome. Good agreement was found between theoretical and measured CdA with varying disc sizes (95% limits of agreement = -0.012 to 0.009 m<sup>2</sup>). A high level of reliability was demonstrated during Experiment 2 with strong intraclass correlation (0.99) and small coefficient of variation (1.67%). Findings of this study demonstrate BR is a valid and reliable device for measuring real-time CdA during cycling in an indoor velodrome.

European Journal of Sport ScienceVol. 25(12)
University of Kent (GB)
Openalex Percentile: Top 53%
Sports Performance and Training
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.