Endovascular Treatment of Ruptured and Unruptured Wide-Neck Intracranial Aneurysms Using LVIS EVO Stent-Assisted Coiling: Mid-Term Results

<b>Background</b>: Stent-assisted coiling (SAC) is an established treatment for wide-neck intracranial aneurysms. The LVIS EVO stent is a new-generation braided device with improved navigability and radiopacity. We evaluated the safety, feasibility, and mid-term outcomes of LVIS EVO SAC in ruptured and unruptured aneurysms. <b>Methods</b>: We retrospectively analyzed 242 consecutive patients treated and evaluated from 2020 to 2025; 63 (26.0%) presented with ruptured and 179 (74.0%) with unruptured aneurysms. Aneurysm occlusion was graded by the Raymond-Roy occlusion classification (RROC) on immediate DSA and at 12-18 months using 3T MR angiography. Clinical outcomes were assessed with the modified Rankin Scale (mRS). <b>Results</b>: Stent delivery succeeded in all cases. Adjunctive angioplasty was required in three procedures. Thromboembolic events occurred in six patients, including four in-stent thromboses treated with eptyfibatide, procedure-related SAH in three, and femoral hematomas in five. Mid-term imaging was available in 228 patients (51 SAH, 177 non-SAH). Adequate occlusion (RROC I-II) was achieved in 48/51 SAH (94.1%) and 169/177 non-SAH (95.5%). Residual sac filling (RROC III) occurred in 11/228 (4.8%), and all retreated. Favorable outcome (mRS 0-2) was observed in 49/63 SAH (77.8%) and 170/179 non-SAH (95.0%). Mortality was 12/63 (19.0%) in SAH-attributed to initial hemorrhage severity-and 2/179 (1.1%) in non-SAH (Takotsubo syndrome, leukemia). <b>Conclusions</b>: LVIS EVO SAC is a safe and effective option for ruptured and unruptured wide-neck aneurysms, yielding high rates of durable occlusion and favorable functional outcomes. Mid-term data support its reliability as an alternative to other endovascular strategies.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-11-28
DOI
https://doi.org/10.3390/jcm14238457
Primary Topic
Intracranial Aneurysms: Treatment and Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Endovascular Treatment of Ruptured and Unruptured Wide-Neck Intracranial Aneurysms Using LVIS EVO Stent-Assisted Coiling: Mid-Term Results

Leszek Sagan, Wojciech Poncyljusz, Konrad Jarosz, Kinga Kubiak et al.
Journal of Clinical Medicine
Intracranial Aneurysms: Treatment and Complications
article

Endovascular Treatment of Ruptured and Unruptured Wide-Neck Intracranial Aneurysms Using LVIS EVO Stent-Assisted Coiling: Mid-Term Results

Leszek Sagan, Wojciech Poncyljusz, Konrad Jarosz, Kinga Kubiak, Elżbieta Włodarczyk
article en

Abstract

<b>Background</b>: Stent-assisted coiling (SAC) is an established treatment for wide-neck intracranial aneurysms. The LVIS EVO stent is a new-generation braided device with improved navigability and radiopacity. We evaluated the safety, feasibility, and mid-term outcomes of LVIS EVO SAC in ruptured and unruptured aneurysms. <b>Methods</b>: We retrospectively analyzed 242 consecutive patients treated and evaluated from 2020 to 2025; 63 (26.0%) presented with ruptured and 179 (74.0%) with unruptured aneurysms. Aneurysm occlusion was graded by the Raymond-Roy occlusion classification (RROC) on immediate DSA and at 12-18 months using 3T MR angiography. Clinical outcomes were assessed with the modified Rankin Scale (mRS). <b>Results</b>: Stent delivery succeeded in all cases. Adjunctive angioplasty was required in three procedures. Thromboembolic events occurred in six patients, including four in-stent thromboses treated with eptyfibatide, procedure-related SAH in three, and femoral hematomas in five. Mid-term imaging was available in 228 patients (51 SAH, 177 non-SAH). Adequate occlusion (RROC I-II) was achieved in 48/51 SAH (94.1%) and 169/177 non-SAH (95.5%). Residual sac filling (RROC III) occurred in 11/228 (4.8%), and all retreated. Favorable outcome (mRS 0-2) was observed in 49/63 SAH (77.8%) and 170/179 non-SAH (95.0%). Mortality was 12/63 (19.0%) in SAH-attributed to initial hemorrhage severity-and 2/179 (1.1%) in non-SAH (Takotsubo syndrome, leukemia). <b>Conclusions</b>: LVIS EVO SAC is a safe and effective option for ruptured and unruptured wide-neck aneurysms, yielding high rates of durable occlusion and favorable functional outcomes. Mid-term data support its reliability as an alternative to other endovascular strategies.

Journal of Clinical MedicineVol. 14(23)
Pomeranian Medical University (PL)
Openalex Percentile: Top 49%
Intracranial Aneurysms: Treatment and Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines