A low-noise low-impedance powered knee prosthesis with direct ball screw drive and torque-sensitive actuation

The standard of care for individuals with above-knee amputation is the microprocessor-controlled knee prosthesis-a lightweight and quiet device that can actively regulate joint resistance but cannot generate positive power like biological legs during ambulation. Powered prostheses aim to address this limitation with robotic actuators. However, limitations of conventional robotic actuators result in powered prostheses that are either heavy, loud, and have high joint impedance or lack sufficient torque and power to replicate key biomechanical functions of the biological leg. These limitations have limited the clinical success of powered knee prostheses. In this paper, we show that combining quasi-direct drive with a variable transmission in a novel torque-sensitive actuator can overcome the limitations of conventional actuators in robotic knee prostheses. Theoretical analysis shows that this combination of technologies substantially extends the range of torques and speeds of an electromechanical actuator without increasing its output impedance. Mechatronics implementation of the proposed design concept into a robotic knee prosthesis confirms the torque, speed, and output impedance improvements predicted by theoretical modeling. Amputee testing verifies that the proposed knee prosthesis can provide joint torques and speeds up to 145 Nm and 550 deg/s, enabling the user to ambulate on stairs and walk at 2.5 m/s. The prosthesis achieves lower impedance than the biological knee and approximates the weight (1.9 kg) and noise (45-53 dBA) of passive microprocessor-controlled knee prostheses. By enabling lightweight, quiet, and powerful prostheses, the proposed actuation concept has the potential to improve the quality of life in individuals with above-knee amputations.

Authors

Institutions

Publication Details

Journal
The International Journal of Robotics Research
Published
2025-11-28
DOI
https://doi.org/10.1177/02783649251383018
Primary Topic
Prosthetics and Rehabilitation Robotics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A low-noise low-impedance powered knee prosthesis with direct ball screw drive and torque-sensitive actuation

Tommaso Lenzi, Lukas Gabert, Brendon Ortolano
The International Journal of Robotics Research
Prosthetics and Rehabilitation Robotics
article

A low-noise low-impedance powered knee prosthesis with direct ball screw drive and torque-sensitive actuation

Tommaso Lenzi, Lukas Gabert, Brendon Ortolano
article en

Abstract

The standard of care for individuals with above-knee amputation is the microprocessor-controlled knee prosthesis-a lightweight and quiet device that can actively regulate joint resistance but cannot generate positive power like biological legs during ambulation. Powered prostheses aim to address this limitation with robotic actuators. However, limitations of conventional robotic actuators result in powered prostheses that are either heavy, loud, and have high joint impedance or lack sufficient torque and power to replicate key biomechanical functions of the biological leg. These limitations have limited the clinical success of powered knee prostheses. In this paper, we show that combining quasi-direct drive with a variable transmission in a novel torque-sensitive actuator can overcome the limitations of conventional actuators in robotic knee prostheses. Theoretical analysis shows that this combination of technologies substantially extends the range of torques and speeds of an electromechanical actuator without increasing its output impedance. Mechatronics implementation of the proposed design concept into a robotic knee prosthesis confirms the torque, speed, and output impedance improvements predicted by theoretical modeling. Amputee testing verifies that the proposed knee prosthesis can provide joint torques and speeds up to 145 Nm and 550 deg/s, enabling the user to ambulate on stairs and walk at 2.5 m/s. The prosthesis achieves lower impedance than the biological knee and approximates the weight (1.9 kg) and noise (45-53 dBA) of passive microprocessor-controlled knee prostheses. By enabling lightweight, quiet, and powerful prostheses, the proposed actuation concept has the potential to improve the quality of life in individuals with above-knee amputations.

The International Journal of Robotics Research
University of Utah (US), Rocky Mountain University of Health Professions (US)
Openalex Percentile: Top 64%
Prosthetics and Rehabilitation Robotics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.