Clinical value of dual-energy CT parameters combined with morphological features in predicting graves’ ophthalmopathy

To investigate the diagnostic value of dual-energy computed tomography (DECT)–derived quantitative parameters combined with morphological features for assessing subtle orbital tissue changes in Graves’ ophthalmopathy (GO), and to evaluate their feasibility as imaging biomarkers throughout the disease course. Data from patients suspected of having GO were retrospectively collected. All these patients underwent DECT scans and had no history of thyroid function treatment or other medical history, which may have affected the measurement of orbital tissues. Three clinical features, four morphological features, and twenty-four DECT parameters were measured. The overall data were divided into training and test cohorts. Univariate and multivariate analyses were applied to select relevant parameters and construct a nomogram. Among the 206 patients suspected of having GO, 134 patients were diagnosed as positive for GO (GO+), and 72 patients were diagnosed as negative (GO-) according to relevant diagnostic criteria. (1) The average thickness, average width, weighted average thickness and weighted average width of orbital muscles significantly differed between the GO + and GO- groups (p < 0.05). (2) The minimum and average values of electron density in orbital muscles and lacrimal glands were significantly different (p < 0.05). (3) A nomogram was constructed to predict the risk of GO, and the area under the curve, sensitivity, and specificity in the training and test cohorts were 0.812, 92.1%, and 59.5% and 0.825, 82.9%, and 71.9%, respectively. DECT parameters combined with morphological features not only can be used as robust predictive indicators for diagnosing GO but also represent promising novel biomarkers that may increase the precision and objectivity of clinical assessments.

Authors

Institutions

Publication Details

Journal
BMC Medical Imaging
Published
2025-11-28
DOI
https://doi.org/10.1186/s12880-025-02044-x
Primary Topic
Ophthalmology and Eye Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical value of dual-energy CT parameters combined with morphological features in predicting graves’ ophthalmopathy

Zixuan Ma, Tingting Shi, Wei Li, Dandan Liu et al.
BMC Medical Imaging
Ophthalmology and Eye Disorders
article

Clinical value of dual-energy CT parameters combined with morphological features in predicting graves’ ophthalmopathy

Zixuan Ma, Tingting Shi, Wei Li, Dandan Liu, Xiaomei Lü, Yongxian Zhang, Yantao Niu, Lin Yuan
article en

Abstract

To investigate the diagnostic value of dual-energy computed tomography (DECT)–derived quantitative parameters combined with morphological features for assessing subtle orbital tissue changes in Graves’ ophthalmopathy (GO), and to evaluate their feasibility as imaging biomarkers throughout the disease course. Data from patients suspected of having GO were retrospectively collected. All these patients underwent DECT scans and had no history of thyroid function treatment or other medical history, which may have affected the measurement of orbital tissues. Three clinical features, four morphological features, and twenty-four DECT parameters were measured. The overall data were divided into training and test cohorts. Univariate and multivariate analyses were applied to select relevant parameters and construct a nomogram. Among the 206 patients suspected of having GO, 134 patients were diagnosed as positive for GO (GO+), and 72 patients were diagnosed as negative (GO-) according to relevant diagnostic criteria. (1) The average thickness, average width, weighted average thickness and weighted average width of orbital muscles significantly differed between the GO + and GO- groups (p < 0.05). (2) The minimum and average values of electron density in orbital muscles and lacrimal glands were significantly different (p < 0.05). (3) A nomogram was constructed to predict the risk of GO, and the area under the curve, sensitivity, and specificity in the training and test cohorts were 0.812, 92.1%, and 59.5% and 0.825, 82.9%, and 71.9%, respectively. DECT parameters combined with morphological features not only can be used as robust predictive indicators for diagnosing GO but also represent promising novel biomarkers that may increase the precision and objectivity of clinical assessments.

BMC Medical ImagingVol. 25(1)
Beijing Tongren Hospital (CN), Philips (Finland) (FI), Capital Medical University (CN), Beijing Friendship Hospital (CN)
Openalex Percentile: Top 49%
Ophthalmology and Eye Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.