Ultrasensitive and Label-Free Detection of Phosphorylated Tau-217 Protein in Alzheimer’s Disease Using Carbon Nanotube Field-Effect Transistor (CNT-FET) Biosensor

Early diagnosis of Alzheimer's disease (AD) remains challenging due to the extremely low concentration of relevant biomarkers and the limited sensitivity of conventional detection techniques. In this study, we present a carbon nanotube field-effect transistor (CNT-FET) immunosensor for label-free detection of phosphorylated tau at threonine 217 (p-tau217). The device employs a Y<sub>2</sub>O<sub>3</sub>/HfO<sub>2</sub> dielectric layer and gold nanoparticles (AuNPs) to improve biofunctionalization, with anti-p-tau217 antibodies immobilized on the CNT channels. In phosphate-buffered saline (PBS), the sensor exhibited a linear response over a concentration range of 3 fM to 30 pM (R<sup>2</sup> = 0.973) and achieved a limit of detection (LOD) of 1.66 fM. The device demonstrated high selectivity, with a normalized signal response (NSR) for p-tau217 that was 5-6 times higher than for human serum albumin (HSA) and p-tau231, even at 1000-fold higher concentrations of these interferents. The sensor exhibited reproducibility with a relative standard deviation (RSD) of 4.8% (<i>n</i> = 9) and storage stability with only a 10% decrease in signal after 7 days at 4 °C. Mechanistic analysis indicated that the net positive charge and structural flexibility of the p-tau217 peptide led to a reduction in drain current upon binding, consistent with electrostatic gating effects in p-type CNT-FETs. Current limitations include the absence of standardized p-tau217 reference materials. Future work will focus on validation with clinical samples. This CNT-FET platform enables rapid, minimally invasive detection of p-tau217 and holds strong potential for integration into clinical workflows to facilitate early AD diagnosis.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2025-11-27
DOI
https://doi.org/10.3390/bios15120784
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrasensitive and Label-Free Detection of Phosphorylated Tau-217 Protein in Alzheimer’s Disease Using Carbon Nanotube Field-Effect Transistor (CNT-FET) Biosensor

Ke-Yu Yao, Duo Wai‐Chi Wong, James Chung‐Wai Cheung, Jiao Wang et al.
Biosensors
Electrochemical sensors and biosensors
article

Ultrasensitive and Label-Free Detection of Phosphorylated Tau-217 Protein in Alzheimer’s Disease Using Carbon Nanotube Field-Effect Transistor (CNT-FET) Biosensor

Ke-Yu Yao, Duo Wai‐Chi Wong, James Chung‐Wai Cheung, Jiao Wang, Jiahua Li
article en

Abstract

Early diagnosis of Alzheimer's disease (AD) remains challenging due to the extremely low concentration of relevant biomarkers and the limited sensitivity of conventional detection techniques. In this study, we present a carbon nanotube field-effect transistor (CNT-FET) immunosensor for label-free detection of phosphorylated tau at threonine 217 (p-tau217). The device employs a Y<sub>2</sub>O<sub>3</sub>/HfO<sub>2</sub> dielectric layer and gold nanoparticles (AuNPs) to improve biofunctionalization, with anti-p-tau217 antibodies immobilized on the CNT channels. In phosphate-buffered saline (PBS), the sensor exhibited a linear response over a concentration range of 3 fM to 30 pM (R<sup>2</sup> = 0.973) and achieved a limit of detection (LOD) of 1.66 fM. The device demonstrated high selectivity, with a normalized signal response (NSR) for p-tau217 that was 5-6 times higher than for human serum albumin (HSA) and p-tau231, even at 1000-fold higher concentrations of these interferents. The sensor exhibited reproducibility with a relative standard deviation (RSD) of 4.8% (<i>n</i> = 9) and storage stability with only a 10% decrease in signal after 7 days at 4 °C. Mechanistic analysis indicated that the net positive charge and structural flexibility of the p-tau217 peptide led to a reduction in drain current upon binding, consistent with electrostatic gating effects in p-type CNT-FETs. Current limitations include the absence of standardized p-tau217 reference materials. Future work will focus on validation with clinical samples. This CNT-FET platform enables rapid, minimally invasive detection of p-tau217 and holds strong potential for integration into clinical workflows to facilitate early AD diagnosis.

BiosensorsVol. 15(12)
Hong Kong Polytechnic University (HK), Shenzhen Polytechnic University (CN), Hubei Provincial Hospital of Traditional Chinese Medicine (CN)
Innovation and Technology Commission, Innovation and Technology Fund
Openalex Percentile: Top 63%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.