Rectus Femoris and Gastrocnemius EMG Driven Cheonjiin Speller for Korean Text Input

Our study introduces a surface electromyography (sEMG)-based Cheonjiin speller system developed to assist individuals with restricted hand mobility. The interface incorporates a directional control framework-comprising up, down, left, right, and select commands-integrated with a Korean keyboard layout to enable efficient and accessible text input. Two-channel surface EMG signals were recorded from the rectus femoris and gastrocnemius muscles at a sampling rate of 200 Hz using an EMG acquisition module. The signals were processed in real time using notch and bandpass filtering, followed by full-wave rectification. To decode user intent, three physiologically interpretable time-domain features-root mean square (RMS), slope sign change (SSC), and peak amplitude-were extracted and subsequently used for classification. The Cheonjiin speller was implemented in Python 3.10.8 and operated through directional cursor navigation. System performance was quantitatively evaluated in two experiments: in Experiment 1, recognition accuracy for five discrete commands reached an average of 90.0%, while Experiment 2, involving continuous Korean word and sentence input, achieved an average accuracy of 88.65%. Across both experimental conditions, the system attained an average information transfer rate (ITR) of 96.19 bits/min, confirming efficient real-time communication capability. The results demonstrate that high recognition performance can be achieved using simple, low-computation features without deep learning models, confirming the feasibility of real-time implementation in resource-limited environments. Overall, the proposed speller system exhibits high operability, accessibility, and practical usability in constrained conditions and holds potential for integration into augmentative and alternative communication (AAC) systems for users with motor impairments. Moreover, its lightweight architecture, minimal computational load, and flexible directional control structure make it adaptable to a wide range of assistive and wearable technology applications.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-11-27
DOI
https://doi.org/10.3390/s25237243
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rectus Femoris and Gastrocnemius EMG Driven Cheonjiin Speller for Korean Text Input

Seongwan Kim, Seung Ho Choi, Ji Won Ahn, G.Y. Yu et al.
Sensors
Muscle activation and electromyography studies
article

Rectus Femoris and Gastrocnemius EMG Driven Cheonjiin Speller for Korean Text Input

Seongwan Kim, Seung Ho Choi, Ji Won Ahn, G.Y. Yu, Young-Seek Seok
article en

Abstract

Our study introduces a surface electromyography (sEMG)-based Cheonjiin speller system developed to assist individuals with restricted hand mobility. The interface incorporates a directional control framework-comprising up, down, left, right, and select commands-integrated with a Korean keyboard layout to enable efficient and accessible text input. Two-channel surface EMG signals were recorded from the rectus femoris and gastrocnemius muscles at a sampling rate of 200 Hz using an EMG acquisition module. The signals were processed in real time using notch and bandpass filtering, followed by full-wave rectification. To decode user intent, three physiologically interpretable time-domain features-root mean square (RMS), slope sign change (SSC), and peak amplitude-were extracted and subsequently used for classification. The Cheonjiin speller was implemented in Python 3.10.8 and operated through directional cursor navigation. System performance was quantitatively evaluated in two experiments: in Experiment 1, recognition accuracy for five discrete commands reached an average of 90.0%, while Experiment 2, involving continuous Korean word and sentence input, achieved an average accuracy of 88.65%. Across both experimental conditions, the system attained an average information transfer rate (ITR) of 96.19 bits/min, confirming efficient real-time communication capability. The results demonstrate that high recognition performance can be achieved using simple, low-computation features without deep learning models, confirming the feasibility of real-time implementation in resource-limited environments. Overall, the proposed speller system exhibits high operability, accessibility, and practical usability in constrained conditions and holds potential for integration into augmentative and alternative communication (AAC) systems for users with motor impairments. Moreover, its lightweight architecture, minimal computational load, and flexible directional control structure make it adaptable to a wide range of assistive and wearable technology applications.

SensorsVol. 25(23)
Yonsei University (KR), Rural Development Administration (KR)
Openalex Percentile: Top 64%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.