Magnetically Retrievable Platinum Nanoreporters for Efficient Lateral Flow Immunoassay in Complex Bio‐Samples

Lateral flow immunoassays (LFIAs) are widely used for point-of-care diagnostics, but their development is challenged by the complexity and variability of patient samples. In particular, LFIAs often exhibit reduced sensitivity and specificity when used with patient samples, compared to their performance with analyte-spiked idealized matrices. Patient samples are inherently complex, with variations in physical and biochemical properties between patients. This complexity has consequences for the performance of LFIAs, and can result in non-specific binding on the test line, discoloration of the nitrocellulose membrane, and incomplete sample flow along the test strip. To address these challenges, a magnetically retrievable platinum nanoreporter (termed Pt@Fe<sub>3</sub>O<sub>4</sub>) is developed for LFIAs. Leveraging the magnetic properties of the Fe<sub>3</sub>O<sub>4</sub> core, magnetic separation is utilized to enable the purification and concentration of target antigens from complex human matrices, including serum, saliva, and even stool samples. This also eliminates assay inconsistencies caused by inter-sample variability. Further, the suitability of Pt@Fe<sub>3</sub>O<sub>4</sub> nanoreporters has been explored for use as detection probes in LFIAs. Signal enhancement is demonstrated by the utilization of the magnetic and enzyme-mimicking activity of the nanoreporter, resulting in a marked improvement in sensitivity, as evidenced by a 2- to 4-fold decrease in the visual limit of detection.

Authors

Institutions

Publication Details

Journal
Small
Published
2025-11-28
DOI
https://doi.org/10.1002/smll.202506622
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Magnetically Retrievable Platinum Nanoreporters for Efficient Lateral Flow Immunoassay in Complex Bio‐Samples

Luca Panariello, André Shamsabadi, Adam Creamer, Yuxi Cheng et al.
Small
Biosensors and Analytical Detection
article

Magnetically Retrievable Platinum Nanoreporters for Efficient Lateral Flow Immunoassay in Complex Bio‐Samples

Luca Panariello, André Shamsabadi, Adam Creamer, Yuxi Cheng, Thomas Gervais, Ali Vaughan, Chris Sadler, Kathleen Lupien
article en

Abstract

Lateral flow immunoassays (LFIAs) are widely used for point-of-care diagnostics, but their development is challenged by the complexity and variability of patient samples. In particular, LFIAs often exhibit reduced sensitivity and specificity when used with patient samples, compared to their performance with analyte-spiked idealized matrices. Patient samples are inherently complex, with variations in physical and biochemical properties between patients. This complexity has consequences for the performance of LFIAs, and can result in non-specific binding on the test line, discoloration of the nitrocellulose membrane, and incomplete sample flow along the test strip. To address these challenges, a magnetically retrievable platinum nanoreporter (termed Pt@Fe<sub>3</sub>O<sub>4</sub>) is developed for LFIAs. Leveraging the magnetic properties of the Fe<sub>3</sub>O<sub>4</sub> core, magnetic separation is utilized to enable the purification and concentration of target antigens from complex human matrices, including serum, saliva, and even stool samples. This also eliminates assay inconsistencies caused by inter-sample variability. Further, the suitability of Pt@Fe<sub>3</sub>O<sub>4</sub> nanoreporters has been explored for use as detection probes in LFIAs. Signal enhancement is demonstrated by the utilization of the magnetic and enzyme-mimicking activity of the nanoreporter, resulting in a marked improvement in sensitivity, as evidenced by a 2- to 4-fold decrease in the visual limit of detection.

SmallVol. 22(2)
Karolinska Institutet (SE), University of Oxford (GB), CRUK/MRC Oxford Institute for Radiation Oncology (GB), Oxford BioMedica (United Kingdom) (GB), Polytechnique Montréal (CA), Imperial College London (GB)
Openalex Percentile: Top 64%
Biosensors and Analytical Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.