Characterization of a high detection-sensitivity atmospheric pressure interface time-of-flight mass spectrometer

Abstract. We have characterised a new Atmospheric-Pressure-interface Time-of-Flight Mass Spectrometer, equipped with an octapole ion trap for accumulating the sampled ions before orthogonally accelerating them into the mass analyser. The characterisation has been carried out using ion standards produced by electrospray ionisation, that were subsequently mobility-selected by a differential mobility analyser operated at atmospheric pressure. Our results show that the detection sensitivity (or limit of detection) of the mass spectrometer is in the parts per quintillion (i.e., 10−3 parts per quadrillion, ppq; which is ∼ 30 ions cm−3) range with temporal resolutions of 1 s. When increasing the temporal resolution up to 1 min, the detection sensitivity can be reduced to the 10 parts per sextillion (i.e., 10−5 ppq; which is ∼ 0.3 ions cm−3) range, enabling the system to measure gaseous ions of extremely low concentrations. In contrast to other mass spectrometers that employ spectra accumulation to improve the detection sensitivity for atmospheric observations, ion accumulation amplifies the signal without increasing the noise level; something that among others is highly important for probing short-lived ionic clusters during new particle formation events in the atmospheric environment. We also show that the mass spectrometer has a transmission of up to 1 %, and a mass resolution of 23 000 for ionic masses of ca. 600 Da, while it can be used in ways to induce collision dissociation of the sampled ions by tuning the operating conditions of the Atmospheric-Pressure-interface stage.

Authors

Institutions

Publication Details

Journal
Atmospheric measurement techniques
Published
2025-11-28
DOI
https://doi.org/10.5194/amt-18-7075-2025
Citations
1
Primary Topic
Atmospheric chemistry and aerosols
Type
article
Field-Weighted Citation Impact
1.30

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Characterization of a high detection-sensitivity atmospheric pressure interface time-of-flight mass spectrometer

Alexandros Lekkas, Somnath Bhowmick, Fabian Schmidt-Ott, Dimitris Papanastasiou et al.
1 citations
Atmospheric measurement techniques
Atmospheric chemistry and aerosols
1.30
article

Characterization of a high detection-sensitivity atmospheric pressure interface time-of-flight mass spectrometer

Alexandros Lekkas, Somnath Bhowmick, Fabian Schmidt-Ott, Dimitris Papanastasiou, George Biskos, Anne Maißer
article en
1 citations

Abstract

Abstract. We have characterised a new Atmospheric-Pressure-interface Time-of-Flight Mass Spectrometer, equipped with an octapole ion trap for accumulating the sampled ions before orthogonally accelerating them into the mass analyser. The characterisation has been carried out using ion standards produced by electrospray ionisation, that were subsequently mobility-selected by a differential mobility analyser operated at atmospheric pressure. Our results show that the detection sensitivity (or limit of detection) of the mass spectrometer is in the parts per quintillion (i.e., 10−3 parts per quadrillion, ppq; which is ∼ 30 ions cm−3) range with temporal resolutions of 1 s. When increasing the temporal resolution up to 1 min, the detection sensitivity can be reduced to the 10 parts per sextillion (i.e., 10−5 ppq; which is ∼ 0.3 ions cm−3) range, enabling the system to measure gaseous ions of extremely low concentrations. In contrast to other mass spectrometers that employ spectra accumulation to improve the detection sensitivity for atmospheric observations, ion accumulation amplifies the signal without increasing the noise level; something that among others is highly important for probing short-lived ionic clusters during new particle formation events in the atmospheric environment. We also show that the mass spectrometer has a transmission of up to 1 %, and a mass resolution of 23 000 for ionic masses of ca. 600 Da, while it can be used in ways to induce collision dissociation of the sampled ions by tuning the operating conditions of the Atmospheric-Pressure-interface stage.

Atmospheric measurement techniquesVol. 18(22)
University of Helsinki (FI), Cyprus Institute (CY), National Centre of Scientific Research "Demokritos" (GR), Delft University of Technology (NL)
European Commission, Research and Innovation Foundation, European Regional Development Fund
Openalex Percentile: Top 16%
Atmospheric chemistry and aerosols
1.30
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.