Defining Fault Ride-Through Curves for Bess Integration in Turkish Transmission Grid

Abstract As renewable energy integration grows, managing its intermittent nature has become a key challenge for system operators. Energy storage, especially Battery Energy Storage Systems (BESS), helps address this but adds complexity—particularly in hybrid facilities. Clear grid codes are essential to ensure stability and smooth integration. While Türkiye’s Transmission System Operator (TEİAŞ) had established Low Voltage Ride Through (LVRT) requirements for wind and solar, BESS-specific criteria were only introduced in late 2024. Since introduced criteria demanded real-time testing to validate BESS performance during faults, this study explores new LVRT and fault response requirements for standalone and hybrid BESS in Türkiye’s transmission grid. Through the simulations regions were selected based on short-circuit power variability, and using DigSILENT PowerFactory software, BESS responses under different fault scenarios are analyzed. The results inform a nationwide framework for BESS fault ride-through capabilities.

Authors

Institutions

Publication Details

Journal
B&H eletrical engineering
Published
2025-11-27
DOI
https://doi.org/10.2478/bhee-2025-0019
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Defining Fault Ride-Through Curves for Bess Integration in Turkish Transmission Grid

Kamil Çağatay Bayındır, Ümit Çetinkaya, Soner Güler
B&H eletrical engineering
Microgrid Control and Optimization
article

Defining Fault Ride-Through Curves for Bess Integration in Turkish Transmission Grid

Kamil Çağatay Bayındır, Ümit Çetinkaya, Soner Güler
article en

Abstract

Abstract As renewable energy integration grows, managing its intermittent nature has become a key challenge for system operators. Energy storage, especially Battery Energy Storage Systems (BESS), helps address this but adds complexity—particularly in hybrid facilities. Clear grid codes are essential to ensure stability and smooth integration. While Türkiye’s Transmission System Operator (TEİAŞ) had established Low Voltage Ride Through (LVRT) requirements for wind and solar, BESS-specific criteria were only introduced in late 2024. Since introduced criteria demanded real-time testing to validate BESS performance during faults, this study explores new LVRT and fault response requirements for standalone and hybrid BESS in Türkiye’s transmission grid. Through the simulations regions were selected based on short-circuit power variability, and using DigSILENT PowerFactory software, BESS responses under different fault scenarios are analyzed. The results inform a nationwide framework for BESS fault ride-through capabilities.

B&H eletrical engineeringVol. 19(2)
Turkish Electro Technology (Turkey) (TR), Ankara Yıldırım Beyazıt University (TR)
Openalex Percentile: Top 54%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Defining Fault Ride-Through Curves for Bess Integration in Turkish Transmission Grid — Kamil Çağatay Bayındır, Ümit Çetinkaya, et al. · B&H eletrical engineering (2025) | TGRS Research Map | TGRS