Dual miniplate internal fixation for forearm diaphysis fractures: a clinical and biomechanical study

Purpose: Forearm diaphyseal fractures require anatomical reduction and stable internal fixation to restore pronation and supination function. Conventional 3.5-mm plates are effective but can be associated with hardware irritation and refracture after implant removal. Dual miniplate fixation using low-profile plates may offer a technically advantageous alternative. This study investigated the clinical outcomes and biomechanical performance of dual miniplate fixation for forearm shaft fractures.Methods: A retrospective review was conducted of 24 patients (29 fractures) treated with dual low-profile plates. Biomechanical testing was performed using synthetic radius models with three fixation constructs: a single 3.5-mm locking compression plate (LCP), dual 2.4-mm LCPs with non-locking screws, and dual 2.4-mm LCPs with mixed locking and non-locking screws. Outcomes included torsional stiffness, axial distraction, cantilever bending stiffness, and failure load.Results: All fractures achieved union, with a mean union time of 119.2 days. Two cases of delayed union and one metal failure were observed. Torsional stiffness and failure load were significantly greater in patients treated with a single 3.5-mm plate, while no significant differences were noted in axial distraction or anteroposterior bending stiffness.Conclusion: Despite lower biomechanical performance than the conventional 3.5-mm plate, dual miniplate fixation achieved satisfactory clinical outcomes with appropriate postoperative protocols. This technique may be a reliable alternative for selected fracture patterns if appropriate postoperative protocols are followed.

Authors

Institutions

Publication Details

Journal
Archives of Hand and Microsurgery
Published
2025-11-28
DOI
https://doi.org/10.12790/ahm.25.0020
Primary Topic
Bone fractures and treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual miniplate internal fixation for forearm diaphysis fractures: a clinical and biomechanical study

Gi Jun Lee, Hyo-Kon Kim, Soo-Young Jeong, Jin Sik Park et al.
Archives of Hand and Microsurgery
Bone fractures and treatments
article

Dual miniplate internal fixation for forearm diaphysis fractures: a clinical and biomechanical study

Gi Jun Lee, Hyo-Kon Kim, Soo-Young Jeong, Jin Sik Park, Young Seok Lee, Incheol Kook, Chang‐Hun Lee, W. P. Andrew Lee
article en

Abstract

Purpose: Forearm diaphyseal fractures require anatomical reduction and stable internal fixation to restore pronation and supination function. Conventional 3.5-mm plates are effective but can be associated with hardware irritation and refracture after implant removal. Dual miniplate fixation using low-profile plates may offer a technically advantageous alternative. This study investigated the clinical outcomes and biomechanical performance of dual miniplate fixation for forearm shaft fractures.Methods: A retrospective review was conducted of 24 patients (29 fractures) treated with dual low-profile plates. Biomechanical testing was performed using synthetic radius models with three fixation constructs: a single 3.5-mm locking compression plate (LCP), dual 2.4-mm LCPs with non-locking screws, and dual 2.4-mm LCPs with mixed locking and non-locking screws. Outcomes included torsional stiffness, axial distraction, cantilever bending stiffness, and failure load.Results: All fractures achieved union, with a mean union time of 119.2 days. Two cases of delayed union and one metal failure were observed. Torsional stiffness and failure load were significantly greater in patients treated with a single 3.5-mm plate, while no significant differences were noted in axial distraction or anteroposterior bending stiffness.Conclusion: Despite lower biomechanical performance than the conventional 3.5-mm plate, dual miniplate fixation achieved satisfactory clinical outcomes with appropriate postoperative protocols. This technique may be a reliable alternative for selected fracture patterns if appropriate postoperative protocols are followed.

Archives of Hand and MicrosurgeryVol. 30(4)
Eulji University (KR), Daegu Fatima Hospital (KR), Hanyang University Guri Hospital (KR), Hanyang University (KR)
Openalex Percentile: Top 52%
Bone fractures and treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.