Validation of the Bactec system for sterility testing of advanced therapy medicinal product suspensions in Ringer’s Lactate

Ensuring sterility is a key quality requirement in the manufacturing of cell-based medicinal products. This study evaluated the capability of the BACTEC automated microbial detection system to identify viable microorganisms in adipose-derived stem cell-based products suspended in Ringer's Lactate. The validation process comprised four stages: i) sterility testing of uninoculated media to assess reagent quality; ii) growth promotion test to confirm medium performance; iii) suitability testing for compatibility with the sample matrix; iv) confirmation using pharmacopeial methods. All inocula met the European Pharmacopoeia recommendations. Validation was defined as the demonstration that the BACTEC system provides results equivalent to the pharmacopeial sterility test in terms of sensitivity, reliability, and detection time. Evaluated parameters included accuracy, repeatability, and detection limit, following European Pharmacopoeia requirements for alternative microbiological methods. The system successfully detected microbial contamination for all reference strains with a detection limit of 5 CFU and repeatability > 95 %. All microorganisms showed growth within 24-72 h, well inside the 7-day acceptance criterion. Quantitative comparison with the pharmacopeial method demonstrated full concordance (Cohen's κ = 1.0) and a strong correlation of detection times (r = 0.92, p < 0.001). These results confirm that the BACTEC system is a validated and reliable alternative to the pharmacopeial sterility test, providing faster detection without loss of analytical accuracy. The validation supports its applicability for sterility assurance of cell-based materials and integration into quality management during the manufacture of advanced therapy medicinal products.

Authors

Institutions

Publication Details

Journal
Journal of Pharmaceutical and Biomedical Analysis
Published
2025-11-25
DOI
https://doi.org/10.1016/j.jpba.2025.117283
Primary Topic
Safe Handling of Antineoplastic Drugs
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of the Bactec system for sterility testing of advanced therapy medicinal product suspensions in Ringer’s Lactate

Ilona Szabłowska‐Gadomska, Marta Bochyńska-Czyż, Agnieszka Mroczko
Journal of Pharmaceutical and Biomedical Analysis
Safe Handling of Antineoplastic Drugs
article

Validation of the Bactec system for sterility testing of advanced therapy medicinal product suspensions in Ringer’s Lactate

Ilona Szabłowska‐Gadomska, Marta Bochyńska-Czyż, Agnieszka Mroczko
article en

Abstract

Ensuring sterility is a key quality requirement in the manufacturing of cell-based medicinal products. This study evaluated the capability of the BACTEC automated microbial detection system to identify viable microorganisms in adipose-derived stem cell-based products suspended in Ringer's Lactate. The validation process comprised four stages: i) sterility testing of uninoculated media to assess reagent quality; ii) growth promotion test to confirm medium performance; iii) suitability testing for compatibility with the sample matrix; iv) confirmation using pharmacopeial methods. All inocula met the European Pharmacopoeia recommendations. Validation was defined as the demonstration that the BACTEC system provides results equivalent to the pharmacopeial sterility test in terms of sensitivity, reliability, and detection time. Evaluated parameters included accuracy, repeatability, and detection limit, following European Pharmacopoeia requirements for alternative microbiological methods. The system successfully detected microbial contamination for all reference strains with a detection limit of 5 CFU and repeatability > 95 %. All microorganisms showed growth within 24-72 h, well inside the 7-day acceptance criterion. Quantitative comparison with the pharmacopeial method demonstrated full concordance (Cohen's κ = 1.0) and a strong correlation of detection times (r = 0.92, p < 0.001). These results confirm that the BACTEC system is a validated and reliable alternative to the pharmacopeial sterility test, providing faster detection without loss of analytical accuracy. The validation supports its applicability for sterility assurance of cell-based materials and integration into quality management during the manufacture of advanced therapy medicinal products.

Journal of Pharmaceutical and Biomedical AnalysisVol. 270
Medical University of Warsaw (PL)
Openalex Percentile: Top 48%
Safe Handling of Antineoplastic Drugs
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.