A simple, versatile approach for coupling a liquid chromatograph and chemical ionization mass spectrometer for offline analysis of organic aerosol

Abstract. A method is described for coupling a high-performance liquid chromatograph (HPLC) and chemical ionization mass spectrometer (CIMS) for the offline analysis of organic aerosol. It employs a nebulizer interface and the Vaporization Inlet for Aerosols (VIA), allowing for the transmission of analytes from the HPLC eluent into the CIMS inlet. Performance of the HPLC-VIA-CIMS system was assessed through the analysis of carboxylic acid standards, environmental chamber-generated secondary organic aerosol (SOA) formed from the ozonolysis of α-pinene, and ambient OA collected in an urban setting. Chromatographic peak shapes were retained through nebulization and evaporation, providing baseline-resolved separation of C6–C18 carboxylic acids and generating molecular-level detail that is not attainable using HPLC or CIMS alone. Instrument response was found to be linear (R2 > 0.97) over an order of magnitude (0.2–3.0 nmol or 2–30 nmol on column) for each of the 12 standards. Analysis of α-pinene ozonolysis SOA achieved isomer-resolved detection of both monomer and dimer reaction products and, through the use of a diode array detector (DAD), illustrated the preservation of chromatographic peak shape through nebulization and evaporation. The HPLC-VIA-CIMS instrument also shows potential for quantitative analysis, provided that authentic standards can be purchased or synthesized, and semi-quantitative analysis of UV-absorbing compounds such as nitrates and carboxylic acids by using a DAD. The system is compatible with small sample quantities (e.g., 30 µg of α-pinene ozonolysis SOA), allowing for detailed molecular characterization of field-collected SOA, including the identification of several monoterpene oxidation products.

Institutions

Publication Details

Journal
Aerosol Research
Published
2025-11-27
DOI
https://doi.org/10.5194/ar-3-557-2025
Primary Topic
Atmospheric chemistry and aerosols
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A simple, versatile approach for coupling a liquid chromatograph and chemical ionization mass spectrometer for offline analysis of organic aerosol

Aerosol Research
Atmospheric chemistry and aerosols
article

A simple, versatile approach for coupling a liquid chromatograph and chemical ionization mass spectrometer for offline analysis of organic aerosol

article en

Abstract

Abstract. A method is described for coupling a high-performance liquid chromatograph (HPLC) and chemical ionization mass spectrometer (CIMS) for the offline analysis of organic aerosol. It employs a nebulizer interface and the Vaporization Inlet for Aerosols (VIA), allowing for the transmission of analytes from the HPLC eluent into the CIMS inlet. Performance of the HPLC-VIA-CIMS system was assessed through the analysis of carboxylic acid standards, environmental chamber-generated secondary organic aerosol (SOA) formed from the ozonolysis of α-pinene, and ambient OA collected in an urban setting. Chromatographic peak shapes were retained through nebulization and evaporation, providing baseline-resolved separation of C6–C18 carboxylic acids and generating molecular-level detail that is not attainable using HPLC or CIMS alone. Instrument response was found to be linear (R2 > 0.97) over an order of magnitude (0.2–3.0 nmol or 2–30 nmol on column) for each of the 12 standards. Analysis of α-pinene ozonolysis SOA achieved isomer-resolved detection of both monomer and dimer reaction products and, through the use of a diode array detector (DAD), illustrated the preservation of chromatographic peak shape through nebulization and evaporation. The HPLC-VIA-CIMS instrument also shows potential for quantitative analysis, provided that authentic standards can be purchased or synthesized, and semi-quantitative analysis of UV-absorbing compounds such as nitrates and carboxylic acids by using a DAD. The system is compatible with small sample quantities (e.g., 30 µg of α-pinene ozonolysis SOA), allowing for detailed molecular characterization of field-collected SOA, including the identification of several monoterpene oxidation products.

Aerosol ResearchVol. 3(2)
Cooperative Institute for Research in Environmental Sciences (US), University of Colorado Boulder (US), Gwangju Institute of Science and Technology (KR), Aerodyne Research (US)
Openalex Percentile: Top 59%
Atmospheric chemistry and aerosols
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A simple, versatile approach for coupling a liquid chromatograph and chemical ionization mass spectrometer for offline analysis of organic aerosol · Aerosol Research (2025) | TGRS Research Map | TGRS