Motion study on upright patient positioning in walk-through PET: evaluation in a clinical setting

The upright WT-PET scanner presents distinct motion control challenges in clinical practice. This study demonstrates that combining ergonomic supports with breath-holding protocols can effectively reduce patient motion during upright PET imaging; however, a full 30-s breath-hold is not feasible for 70% of patients. Since 50% of patients were able to perform a moderate breath-hold, a two-step acquisition can be performed, each comprising 15 s. Moreover, including a healthy volunteer control group and comparisons with conventional PET confirm both the feasibility and the current limitations of the WT-PET.

Authors

Institutions

Publication Details

Journal
EJNMMI Physics
Published
2025-11-27
DOI
https://doi.org/10.1186/s40658-025-00815-7
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Motion study on upright patient positioning in walk-through PET: evaluation in a clinical setting

Jens Maebe, Yves D’Asseler, Florence M. Muller, Boris Vervenne et al.
EJNMMI Physics
Medical Imaging Techniques and Applications
article

Motion study on upright patient positioning in walk-through PET: evaluation in a clinical setting

Jens Maebe, Yves D’Asseler, Florence M. Muller, Boris Vervenne, Nadia Withofs, Christian Vanhove, Rabia Aziz, Meysam Dadgar, Stefaan Vandenberghe
article en

Abstract

The upright WT-PET scanner presents distinct motion control challenges in clinical practice. This study demonstrates that combining ergonomic supports with breath-holding protocols can effectively reduce patient motion during upright PET imaging; however, a full 30-s breath-hold is not feasible for 70% of patients. Since 50% of patients were able to perform a moderate breath-hold, a two-step acquisition can be performed, each comprising 15 s. Moreover, including a healthy volunteer control group and comparisons with conventional PET confirm both the feasibility and the current limitations of the WT-PET.

EJNMMI PhysicsVol. 12(1)
Ghent University Hospital (BE), Ghent University (BE), Centre Hospitalier Universitaire de Liège (BE), University of Pennsylvania (US), Stanford University (US)
Fonds Wetenschappelijk Onderzoek, Universitair Ziekenhuis Gent, Universiteit Gent, Vlaamse regering
Openalex Percentile: Top 48%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.