Anatomical Analysis of the Femoral Insertions of the Lateral Collateral Ligament and Popliteal Tendon in the Chilean Population: A Magnetic Resonance Imaging Study

Injuries to the posterolateral corner (PLC) of the knee can significantly impair stability and function. In particular, variations in the femoral insertions of the lateral collateral ligament (LCL) and popliteal tendon (PT) may affect surgical planning for PLC injuries. However, these anatomical features are underexplored in the Chilean population. This study seeks to characterize the femoral insertions of the LCL and PT in Chilean patients based on magnetic resonance imaging (MRI) findings. This cross-sectional, observational study was conducted at a single center, including 43 patients aged 18 and older who underwent knee MRI scans. Imaging was performed using a 1.5 Tesla MRI scanner with isotropic voxel dimensions of 0.65 × 0.65 × 0.65 mm. Two musculoskeletal radiologists independently measured the distance between the centroids of the LCL and PT insertion points on the femur. An intraclass correlation coefficient (ICC) was calculated to assess interobserver reliability, and a paired <i>t</i>-test was used to compare the measurements. A <i>p</i>-value < 0.05 was considered statistically significant. Among the 43 patients (51.2% male, 48.8% right knees), the average distance between the LCL and PT insertion centroids was 11.7 mm (standard deviation: 1.61). The measurements by the two radiologists were similar (observer 1: 11.5 mm; observer 2: 11.8 mm), with no significant differences (<i>p</i> = 0.326). The ICC for interobserver agreement was 0.83 (95% confidence interval: 0.69-0.91), indicating high reliability. In this Chilean cohort, the average distance between the LCL and PT femoral insertions was 11.7 mm, a value that differs from previously reported ranges. These findings may help refine surgical approaches to PLC injuries.Level III, cross-sectional observational study.

Authors

Institutions

Publication Details

Journal
The Journal of Knee Surgery
Published
2025-11-27
DOI
https://doi.org/10.1055/a-2756-0076
Primary Topic
Knee injuries and reconstruction techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Anatomical Analysis of the Femoral Insertions of the Lateral Collateral Ligament and Popliteal Tendon in the Chilean Population: A Magnetic Resonance Imaging Study

Jaime Ugarte, Rodrigo Olivieri, José Laso, Esteban Giannini et al.
The Journal of Knee Surgery
Knee injuries and reconstruction techniques
article

Anatomical Analysis of the Femoral Insertions of the Lateral Collateral Ligament and Popliteal Tendon in the Chilean Population: A Magnetic Resonance Imaging Study

Jaime Ugarte, Rodrigo Olivieri, José Laso, Esteban Giannini, Nicolás Franulic, Nicolás Castro, E Donoso
article en

Abstract

Injuries to the posterolateral corner (PLC) of the knee can significantly impair stability and function. In particular, variations in the femoral insertions of the lateral collateral ligament (LCL) and popliteal tendon (PT) may affect surgical planning for PLC injuries. However, these anatomical features are underexplored in the Chilean population. This study seeks to characterize the femoral insertions of the LCL and PT in Chilean patients based on magnetic resonance imaging (MRI) findings. This cross-sectional, observational study was conducted at a single center, including 43 patients aged 18 and older who underwent knee MRI scans. Imaging was performed using a 1.5 Tesla MRI scanner with isotropic voxel dimensions of 0.65 × 0.65 × 0.65 mm. Two musculoskeletal radiologists independently measured the distance between the centroids of the LCL and PT insertion points on the femur. An intraclass correlation coefficient (ICC) was calculated to assess interobserver reliability, and a paired <i>t</i>-test was used to compare the measurements. A <i>p</i>-value < 0.05 was considered statistically significant. Among the 43 patients (51.2% male, 48.8% right knees), the average distance between the LCL and PT insertion centroids was 11.7 mm (standard deviation: 1.61). The measurements by the two radiologists were similar (observer 1: 11.5 mm; observer 2: 11.8 mm), with no significant differences (<i>p</i> = 0.326). The ICC for interobserver agreement was 0.83 (95% confidence interval: 0.69-0.91), indicating high reliability. In this Chilean cohort, the average distance between the LCL and PT femoral insertions was 11.7 mm, a value that differs from previously reported ranges. These findings may help refine surgical approaches to PLC injuries.Level III, cross-sectional observational study.

The Journal of Knee Surgery
Universidad de Los Andes, Chile (CL), Hospital Barros Luco-Trudeau (CL), Universidad Andrés Bello (CL), Hospital Militar de Santiago (CL), Hospital del Trabajador (CL)
Openalex Percentile: Top 44%
Knee injuries and reconstruction techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.