The Effect of Trabeculectomy Approach on Surgically Induced Astigmatism in the Treatment of Open-Angle Glaucoma

Purpose In open-angle glaucoma, trabeculectomy effectively reduces intraocular pressure when medical or laser therapies fail; yet, it typically introduces astigmatism. We conducted a retrospective observational study comparing surgically induced astigmatism (SIA) across three trabeculectomy methods (limbal-based and fornix-based with or without partial-thickness limbal corneal incision) by three surgeons at the University of Iowa Health Care. Methods A chart review was conducted for patients who underwent trabeculectomy for open-angle glaucoma at the University of Iowa Health Care between January 2018 and August 2023. Exclusion criteria included combined phacotrabeculectomy, retinal/corneal comorbidities, concurrent ocular surgeries, and patients under 18 years of age. Pre- and post-operative refractions within two years of surgery were used to calculate SIA. One-tailed analysis of variance (ANOVA), Tukey's Honest Significant Difference test, and chi-square test of independence were performed to compare the surgical approach on SIA and change in the axis of astigmatism. Results The final sample included 87 patients with a mean age of 73.1±11.7 years; 59.8% of patients were women. Twenty-five procedures had a limbus-based approach by Surgeon 1, 23 fornix-based by Surgeon 1, 18 fornix-based by Surgeon 2, and 21 fornix-based by Surgeon 3. While mean SIA ranged from +0.913±0.617 diopters to +1.35±1.47 diopters, there was no significant difference between surgical approaches (p=0.409). Change in axis (p=0.451) or direction of change towards with-the-rule or against-the-rule (p=0.144) did not differ between the surgical approaches. Conclusion This study compared SIA after three trabeculectomy approaches in a single institution. Within our sample, surgical approach was not associated with SIA.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-11-27
DOI
https://doi.org/10.7759/cureus.97955
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Effect of Trabeculectomy Approach on Surgically Induced Astigmatism in the Treatment of Open-Angle Glaucoma

Christian Mays, Nathaniel C. Sears, Hansen Dang, Sean Rivera et al.
Cureus
Glaucoma and retinal disorders
article

The Effect of Trabeculectomy Approach on Surgically Induced Astigmatism in the Treatment of Open-Angle Glaucoma

Christian Mays, Nathaniel C. Sears, Hansen Dang, Sean Rivera, Erin A. Boese, Andrew Pouw, Hend M Al-Kaylani
article en

Abstract

Purpose In open-angle glaucoma, trabeculectomy effectively reduces intraocular pressure when medical or laser therapies fail; yet, it typically introduces astigmatism. We conducted a retrospective observational study comparing surgically induced astigmatism (SIA) across three trabeculectomy methods (limbal-based and fornix-based with or without partial-thickness limbal corneal incision) by three surgeons at the University of Iowa Health Care. Methods A chart review was conducted for patients who underwent trabeculectomy for open-angle glaucoma at the University of Iowa Health Care between January 2018 and August 2023. Exclusion criteria included combined phacotrabeculectomy, retinal/corneal comorbidities, concurrent ocular surgeries, and patients under 18 years of age. Pre- and post-operative refractions within two years of surgery were used to calculate SIA. One-tailed analysis of variance (ANOVA), Tukey's Honest Significant Difference test, and chi-square test of independence were performed to compare the surgical approach on SIA and change in the axis of astigmatism. Results The final sample included 87 patients with a mean age of 73.1±11.7 years; 59.8% of patients were women. Twenty-five procedures had a limbus-based approach by Surgeon 1, 23 fornix-based by Surgeon 1, 18 fornix-based by Surgeon 2, and 21 fornix-based by Surgeon 3. While mean SIA ranged from +0.913±0.617 diopters to +1.35±1.47 diopters, there was no significant difference between surgical approaches (p=0.409). Change in axis (p=0.451) or direction of change towards with-the-rule or against-the-rule (p=0.144) did not differ between the surgical approaches. Conclusion This study compared SIA after three trabeculectomy approaches in a single institution. Within our sample, surgical approach was not associated with SIA.

CureusVol. 17(11)
University of Iowa (US), University of California, Los Angeles (US), Riverview Psychiatric Center (US), University of Iowa Hospitals and Clinics (US), Los Angeles Medical Center (US), Coastal Orthopedics (US), Eye Care Associates (US), Radiology Associates of Albuquerque (US)
Openalex Percentile: Top 49%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.