Design and Performance Analysis of a Thermal Energy Storage System With Steam Extraction and Electric Heating in a Coal‐Fired Power Plant

ABSTRACT To alleviate the impact of the instability of renewable energy power generation on the power grid, coal‐fired power plants (CFPPs) have to undertake peak shaving tasks, which puts forward high requirements for the flexibility of CFPPs. To enhance the flexibility of CFPPs to consume more renewable energy, this paper innovatively proposes a thermal energy storage (TES) model of the main and reheat steam extraction heating coupled with electric heating (mode 1) and compares it with the model only using electric heating (mode 2). During the discharging process, the heat stored in the TES system is utilized to generate the main steam returning to the unit. The results show that for mode 1, during a heat storage and release cycle, the unit can increase the peak shaving capacity of 113.3 MW and provide extra electric power of 74.2 MW. Besides, the comprehensive coal consumption is 327.74 g/kWh, reduced by 10.1 g/kWh, about 2.99%, compared with 30% turbine heat acceptance (THA) condition. The round‐trip efficiency is 53.22%, 18% higher than that in mode 2. In the charging process, the main steam condensate has the most significant influence on the steam/water thermal storage power, accounting for about 66%, with the latent heat exchanger having the highest proportion. Mode 2 has the highest load reduction ability but with the largest irreversible loss. The cold salt temperature and the mass flow of generated steam affect the molten salt mass flow in the charging and discharging processes, respectively. In the TES system, exergy losses mainly come from the electric heater, phase change heat exchangers, and steam ejectors. This study can provide some references for enhancing the flexibility of CFPPs.

Authors

Institutions

Publication Details

Journal
Asia-Pacific Journal of Chemical Engineering
Published
2025-11-27
DOI
https://doi.org/10.1002/apj.70163
Primary Topic
Phase Change Materials Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design and Performance Analysis of a Thermal Energy Storage System With Steam Extraction and Electric Heating in a Coal‐Fired Power Plant

Hao Zhou, Miao Yu, Yuguo Ni, Keliang Liu
Asia-Pacific Journal of Chemical Engineering
Phase Change Materials Research
article

Design and Performance Analysis of a Thermal Energy Storage System With Steam Extraction and Electric Heating in a Coal‐Fired Power Plant

Hao Zhou, Miao Yu, Yuguo Ni, Keliang Liu
article en

Abstract

ABSTRACT To alleviate the impact of the instability of renewable energy power generation on the power grid, coal‐fired power plants (CFPPs) have to undertake peak shaving tasks, which puts forward high requirements for the flexibility of CFPPs. To enhance the flexibility of CFPPs to consume more renewable energy, this paper innovatively proposes a thermal energy storage (TES) model of the main and reheat steam extraction heating coupled with electric heating (mode 1) and compares it with the model only using electric heating (mode 2). During the discharging process, the heat stored in the TES system is utilized to generate the main steam returning to the unit. The results show that for mode 1, during a heat storage and release cycle, the unit can increase the peak shaving capacity of 113.3 MW and provide extra electric power of 74.2 MW. Besides, the comprehensive coal consumption is 327.74 g/kWh, reduced by 10.1 g/kWh, about 2.99%, compared with 30% turbine heat acceptance (THA) condition. The round‐trip efficiency is 53.22%, 18% higher than that in mode 2. In the charging process, the main steam condensate has the most significant influence on the steam/water thermal storage power, accounting for about 66%, with the latent heat exchanger having the highest proportion. Mode 2 has the highest load reduction ability but with the largest irreversible loss. The cold salt temperature and the mass flow of generated steam affect the molten salt mass flow in the charging and discharging processes, respectively. In the TES system, exergy losses mainly come from the electric heater, phase change heat exchangers, and steam ejectors. This study can provide some references for enhancing the flexibility of CFPPs.

Asia-Pacific Journal of Chemical Engineering
Zhejiang Energy Research Institute (CN), Zhejiang Energy Group (China) (CN)
Openalex Percentile: Top 62%
Phase Change Materials Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.