Chimp algorithm based Solar-Hydrogen energy powered UPQC for distribution system

The incorporation of green energy sources into the network, along with the introduction of power electrical devices to regulate loads that are not linear, has significantly influenced power quality (PQ). Nevertheless, PQ is the primary challenge when integrating inconsistent power from renewable sources. Here, the reduced switch converter is selected for the Unified Power Quality Conditioner (UPQC) that is incorporated with the Solar PV Generation System (SPVGS), hydrogen Fuel cell (FC), and Battery Energy Storage Systems (BESS) to handle PQ problems effectively. This paper suggests a hybrid scheme that has the advantageous characteristics of a neural network controller (NNC), Proportional integral derivative controller (PIDC) and Fuzzy logic controller (FLC). NNC with Synchronous reference frame theory (dq) is adopted to generate the reference signals. Additionally, a meta-heuristic-based chimp algorithm (ChOA) is adapted to design the optimized FLC-PIDC hybrid controller for regulating the DC Link voltage (DLV), resistance, inductance, and capacitance variables of filters, proportional integral controller (PIC) gain values of FC and BESS. The primary goal of the suggested approach is to maintain a stable DLV despite fluctuations in both load and SPVGS. The system also seeks to reduce fluctuations in the load voltage and supply current, as well as to reduce sag, interruption, swell, and imbalances caused by variations in the source voltage. Testing the developed mode with four case studies each with a load like nonlinear, balanced, and unbalanced and grid voltage variations with variable irradiation was done to assess its performance. On the other hand, to validate the proposed technique the comparison analysis is conducted using conventional PIC. The proposed approach effectively decreases the total harmonic distortion (THD) to 2.30%, 2.63%, 2.79%, and 2.64%. These values are notably lower than those achieved by other methods in the literature.

Authors

Institutions

Publication Details

Journal
Energy Exploration & Exploitation
Published
2025-11-27
DOI
https://doi.org/10.1177/01445987251390554
Primary Topic
Microgrid Control and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Chimp algorithm based Solar-Hydrogen energy powered UPQC for distribution system

Koganti Srilakshmi, Gummadi Srinivasa Rao, Praveen Kumar Balachandran, K. Sangeetha et al.
Energy Exploration & Exploitation
Microgrid Control and Optimization
article

Chimp algorithm based Solar-Hydrogen energy powered UPQC for distribution system

Koganti Srilakshmi, Gummadi Srinivasa Rao, Praveen Kumar Balachandran, K. Sangeetha, Nagaraju Valluri
article en

Abstract

The incorporation of green energy sources into the network, along with the introduction of power electrical devices to regulate loads that are not linear, has significantly influenced power quality (PQ). Nevertheless, PQ is the primary challenge when integrating inconsistent power from renewable sources. Here, the reduced switch converter is selected for the Unified Power Quality Conditioner (UPQC) that is incorporated with the Solar PV Generation System (SPVGS), hydrogen Fuel cell (FC), and Battery Energy Storage Systems (BESS) to handle PQ problems effectively. This paper suggests a hybrid scheme that has the advantageous characteristics of a neural network controller (NNC), Proportional integral derivative controller (PIDC) and Fuzzy logic controller (FLC). NNC with Synchronous reference frame theory (dq) is adopted to generate the reference signals. Additionally, a meta-heuristic-based chimp algorithm (ChOA) is adapted to design the optimized FLC-PIDC hybrid controller for regulating the DC Link voltage (DLV), resistance, inductance, and capacitance variables of filters, proportional integral controller (PIC) gain values of FC and BESS. The primary goal of the suggested approach is to maintain a stable DLV despite fluctuations in both load and SPVGS. The system also seeks to reduce fluctuations in the load voltage and supply current, as well as to reduce sag, interruption, swell, and imbalances caused by variations in the source voltage. Testing the developed mode with four case studies each with a load like nonlinear, balanced, and unbalanced and grid voltage variations with variable irradiation was done to assess its performance. On the other hand, to validate the proposed technique the comparison analysis is conducted using conventional PIC. The proposed approach effectively decreases the total harmonic distortion (THD) to 2.30%, 2.63%, 2.79%, and 2.64%. These values are notably lower than those achieved by other methods in the literature.

Energy Exploration & ExploitationVol. 44(2)
Siddhartha Medical College (IN), Amhara Agricultural Research Institute (ET), Siddhartha University (NP), Kebri Dehar University, Institute of Science and Technology, Chitkara University (IN)
Openalex Percentile: Top 54%
Microgrid Control and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.