Rapid and sensitive electrochemical detection of paracetamol using EuZrO3-modified carbon paste electrode

The growing prevalence of pharmaceutical contaminants in the environment underscores the urgent need for high-performance, scalable sensing platforms capable of real-time monitoring. In this study, a novel electrochemical sensor based on a europium zirconate (EuZrO<sub>3</sub>)-modified carbon paste electrode (EZO-ME1) was synthesized via a robust high-temperature solid-state route under a reducing atmosphere. The rare-earth based perovskite EZO offers unique redox-active sites, enhanced electrical conductivity, and structural stability, enabling superior electrocatalytic behavior. Detailed physicochemical characterization confirmed the formation of a phase-pure orthorhombic perovskite with nanoscale crystallite dimensions (~ 23 nm, estimated from XRD) and favorable polyhedral coordination, which contribute to efficient surface-confined reactions. Electrochemical performance of EZO-ME1 was evaluated for the detection of paracetamol (PA) as a model analyte. The sensor demonstrated outstanding sensitivity, with a detection limit of 0.096 µM and 0.323 µM, a linear response range of 0.1-1.0 µM, and optimal operation at physiological pH (7.0). Furthermore, the electrode exhibited excellent cycling stability over 25 repetitive scans, high reproducibility across independently fabricated sensors, and negligible baseline drift. Real sample analysis using commercial PA tablets yielded recovery rates between 98% and 103%, confirming the sensor's reliability and practical applicability. This work highlights the multifunctional potential of EZO as an advanced sensing material and its seamless integration into carbon paste electrode platforms, offering a scalable, cost-effective, and high-performance solution for pharmaceutical monitoring and environmental diagnostics.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-11-27
DOI
https://doi.org/10.1038/s41598-025-28851-4
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid and sensitive electrochemical detection of paracetamol using EuZrO3-modified carbon paste electrode

Siddegowda Chandraju, S. Madan Kumar, C. S. Chidan Kumar, T. R. Divakara et al.
Scientific Reports
Electrochemical sensors and biosensors
article

Rapid and sensitive electrochemical detection of paracetamol using EuZrO3-modified carbon paste electrode

Siddegowda Chandraju, S. Madan Kumar, C. S. Chidan Kumar, T. R. Divakara, Abdel-Basit Al-Odayni, P. Sumesh, K. S. Mahesh Lohith
article en

Abstract

The growing prevalence of pharmaceutical contaminants in the environment underscores the urgent need for high-performance, scalable sensing platforms capable of real-time monitoring. In this study, a novel electrochemical sensor based on a europium zirconate (EuZrO<sub>3</sub>)-modified carbon paste electrode (EZO-ME1) was synthesized via a robust high-temperature solid-state route under a reducing atmosphere. The rare-earth based perovskite EZO offers unique redox-active sites, enhanced electrical conductivity, and structural stability, enabling superior electrocatalytic behavior. Detailed physicochemical characterization confirmed the formation of a phase-pure orthorhombic perovskite with nanoscale crystallite dimensions (~ 23 nm, estimated from XRD) and favorable polyhedral coordination, which contribute to efficient surface-confined reactions. Electrochemical performance of EZO-ME1 was evaluated for the detection of paracetamol (PA) as a model analyte. The sensor demonstrated outstanding sensitivity, with a detection limit of 0.096 µM and 0.323 µM, a linear response range of 0.1-1.0 µM, and optimal operation at physiological pH (7.0). Furthermore, the electrode exhibited excellent cycling stability over 25 repetitive scans, high reproducibility across independently fabricated sensors, and negligible baseline drift. Real sample analysis using commercial PA tablets yielded recovery rates between 98% and 103%, confirming the sensor's reliability and practical applicability. This work highlights the multifunctional potential of EZO as an advanced sensing material and its seamless integration into carbon paste electrode platforms, offering a scalable, cost-effective, and high-performance solution for pharmaceutical monitoring and environmental diagnostics.

Scientific ReportsVol. 15(1)
Jagiellonian University (PL), University of Mysore (IN), King Saud University (SA), Seva Mandir (IN), Mandya Institute of Medical Sciences (IN), Indian Institute of Management Bangalore (IN), Visvesvaraya Technological University (IN)
King Saud University
Openalex Percentile: Top 63%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.