Dynamics of Vapor Intrusion under Varying Source Strength

Vapor intrusion (VI) is a dynamic process characterized by strong temporal variability, as field observations show significant fluctuations in indoor air data over periods ranging from days to years. This study develops a semianalytical model to investigate transient vapor migration under varying source strengths (large-volume, diminishing, and fluctuating) and source types (groundwater and soil-gas). For large-volume sources, vertical vapor concentration profiles in soils with high moisture stabilize over 50 years, demonstrating that steady-state screening-level models may mischaracterize long-term exposure risks. The soil diffusion time scale approximates the overall time scale of the VI pathway, identifying subsurface vapor migration as the limiting process. The capillary fringe above groundwater sources slows vapor migration. For finite and diminishing sources, indoor air concentrations rise from zero to a peak value before declining back to zero. Altering the system's influx and outflux can effectively mitigate VI risks: increasing the ratio of the building volume to the source volume shortens the peak arrival time, and increasing the air exchange rate reduces the peak indoor air concentration. For periodic sources, a highly fluctuating attenuation factor indicates that the soil diffusion time scale is comparable to or much smaller than the source period, necessitating time-dependent VI analysis for long-term exposure assessments. Conversely, steady indoor air concentrations at late times suggest that the VI time scale far exceeds the source period, and periodic sources behave similarly to large-volume sources. A linear system approach is proposed to simulate diminishing or sporadically varying source strengths and is applied to a recent VI field test under a fluctuating trichloroethylene groundwater source. The approach effectively generates continuous results from sparse field measurements, with the simulated VI pathway exhibiting patterns consistent with the transient semianalytical model.

Authors

Institutions

Publication Details

Journal
Environmental Science & Technology
Published
2025-11-25
DOI
https://doi.org/10.1021/acs.est.5c05721
Primary Topic
Groundwater flow and contamination studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamics of Vapor Intrusion under Varying Source Strength

Chunhui Lu, Pengzhi Lin, Yuchen Kang, Yu He et al.
Environmental Science & Technology
Groundwater flow and contamination studies
article

Dynamics of Vapor Intrusion under Varying Source Strength

Chunhui Lu, Pengzhi Lin, Yuchen Kang, Yu He, Hong Xiao
article en

Abstract

Vapor intrusion (VI) is a dynamic process characterized by strong temporal variability, as field observations show significant fluctuations in indoor air data over periods ranging from days to years. This study develops a semianalytical model to investigate transient vapor migration under varying source strengths (large-volume, diminishing, and fluctuating) and source types (groundwater and soil-gas). For large-volume sources, vertical vapor concentration profiles in soils with high moisture stabilize over 50 years, demonstrating that steady-state screening-level models may mischaracterize long-term exposure risks. The soil diffusion time scale approximates the overall time scale of the VI pathway, identifying subsurface vapor migration as the limiting process. The capillary fringe above groundwater sources slows vapor migration. For finite and diminishing sources, indoor air concentrations rise from zero to a peak value before declining back to zero. Altering the system's influx and outflux can effectively mitigate VI risks: increasing the ratio of the building volume to the source volume shortens the peak arrival time, and increasing the air exchange rate reduces the peak indoor air concentration. For periodic sources, a highly fluctuating attenuation factor indicates that the soil diffusion time scale is comparable to or much smaller than the source period, necessitating time-dependent VI analysis for long-term exposure assessments. Conversely, steady indoor air concentrations at late times suggest that the VI time scale far exceeds the source period, and periodic sources behave similarly to large-volume sources. A linear system approach is proposed to simulate diminishing or sporadically varying source strengths and is applied to a recent VI field test under a fluctuating trichloroethylene groundwater source. The approach effectively generates continuous results from sparse field measurements, with the simulated VI pathway exhibiting patterns consistent with the transient semianalytical model.

Environmental Science & TechnologyVol. 59(51)
Georgia Institute of Technology (US), Hong Kong Polytechnic University (HK), Hohai University (CN), Sichuan University (CN), Environmental and Water Resources Engineering (IL), State Key Laboratory of Hydrology-Water Resources and Hydraulic Engineering (CN), State Key Laboratory of Hydrology Water Resources and Hydraulic Engineering (CN), State Key Laboratory of Hydraulics and Mountain River Engineering
Openalex Percentile: Top 65%
Groundwater flow and contamination studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.