FZC-TDE: The Algorithm for Real-Time Ultrasonic Stress Measurement at Low Sampling Rates

Micro-nano-sized processing equipment requires high levels of precision, necessitating residual stress measurement to maintain stability. Ultrasonic stress measurement is an effective method but is hindered by high sampling-rate requirements, leading to excessive power consumption and hardware costs. This study presents a low-sampling-rate method based on the novel Frequency-domain Zero-padded Cross-correlation Time Delay Estimation (FZC-TDE) algorithm. Tensile validation experiments determined the minimum hardware sampling-rate requirement: rates below 25 MSps (even with interpolation) fail to characterize temporal delay variations effectively, and a rate of at least 20 times the signal frequency is required for ±10 MPa accuracy. The proposed FZC-TDE utilizes a frequency-domain fusion operation (frequency-domain zero-padding interpolation combined with cross-correlation) to enable real-time, high-resolution delay measurement at low rates. Comparative experiments show that time-domain interpolation methods (Linear, PCH, Cubic Spline) achieve similar stress estimation accuracy at the same rate (e.g., 7.4-8.7 MPa error at 100 MSps), while FZC-TDE (10.3 MPa error) offers superior computational efficiency. At 100 MSps, FZC-TDE maintains a stable computation time (~2.8 ms), while those of interpolation methods increase significantly (20-30 ms) due to higher oversampling factors. Furthermore, FZC-TDE reduces the number of arithmetic operations by 75% (2.26 million vs. ≥9.18 million for 128× oversampling on 1024 points) and exhibits slower computational load growth with oversampling ratios. Thus, FZC-TDE provides an optimal balance of acceptable accuracy and significantly enhanced efficiency, particularly for real-time or resource-constrained applications. This work reduces sampling-rate constraints and supports advancements in micro-nano-sized processing equipment and device performance.

Authors

Institutions

Publication Details

Journal
Micromachines
Published
2025-11-27
DOI
https://doi.org/10.3390/mi16121340
Primary Topic
Ultrasound Imaging and Elastography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

FZC-TDE: The Algorithm for Real-Time Ultrasonic Stress Measurement at Low Sampling Rates

Zhong He, Jun Zhao, Guoqing Gou, Jiakai Chen et al.
Micromachines
Ultrasound Imaging and Elastography
article

FZC-TDE: The Algorithm for Real-Time Ultrasonic Stress Measurement at Low Sampling Rates

Zhong He, Jun Zhao, Guoqing Gou, Jiakai Chen, Bing Chen, Feifei Qiu, Chenshi Luo
article en

Abstract

Micro-nano-sized processing equipment requires high levels of precision, necessitating residual stress measurement to maintain stability. Ultrasonic stress measurement is an effective method but is hindered by high sampling-rate requirements, leading to excessive power consumption and hardware costs. This study presents a low-sampling-rate method based on the novel Frequency-domain Zero-padded Cross-correlation Time Delay Estimation (FZC-TDE) algorithm. Tensile validation experiments determined the minimum hardware sampling-rate requirement: rates below 25 MSps (even with interpolation) fail to characterize temporal delay variations effectively, and a rate of at least 20 times the signal frequency is required for ±10 MPa accuracy. The proposed FZC-TDE utilizes a frequency-domain fusion operation (frequency-domain zero-padding interpolation combined with cross-correlation) to enable real-time, high-resolution delay measurement at low rates. Comparative experiments show that time-domain interpolation methods (Linear, PCH, Cubic Spline) achieve similar stress estimation accuracy at the same rate (e.g., 7.4-8.7 MPa error at 100 MSps), while FZC-TDE (10.3 MPa error) offers superior computational efficiency. At 100 MSps, FZC-TDE maintains a stable computation time (~2.8 ms), while those of interpolation methods increase significantly (20-30 ms) due to higher oversampling factors. Furthermore, FZC-TDE reduces the number of arithmetic operations by 75% (2.26 million vs. ≥9.18 million for 128× oversampling on 1024 points) and exhibits slower computational load growth with oversampling ratios. Thus, FZC-TDE provides an optimal balance of acceptable accuracy and significantly enhanced efficiency, particularly for real-time or resource-constrained applications. This work reduces sampling-rate constraints and supports advancements in micro-nano-sized processing equipment and device performance.

MicromachinesVol. 16(12)
Dongfang Electric Corporation (China) (CN), Southwest Jiaotong University (CN)
Openalex Percentile: Top 48%
Ultrasound Imaging and Elastography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.