In a 7-month-old boy (body weight 7 kg) with congenital heart disease, short bowel syndrome, and gastric motility disorder, conventional insertion of a duodenal feeding tube was unsuccessful (Figure 1). Alternatively, a catheter-based method under fluoroscopy was performed. An angiography catheter (4F multipurpose special; Cordis Corp., Miami Lakes, FL, USA) was inserted nasogastrically into the stomach, then a guide wire (0.014'' Whisper™ ES; Abbott Medical, Santa Clara, CA, USA) was advanced into the duodenum over which the catheter could be pushed (Figure 2A). The course of the duodenum then was visualized by manual contrast injection (Figure 2B). Next, a more stable guide wire (0.018'' Nitrex™; ev3 Inc., Plymouth, MN, USA) was carefully inserted into the distal duodenum. To enable an insertion over-the-wire, the closed tip of an enteral feeding tube (8 F Freka™ Tube; Fresenius Kabi AG, Bad Homburg, Germany) was cut off. To deburr it, the tip was ground down and washed. Using ultrasound gel to improve gliding ability, the tube could be easily advanced into the duodenum via the wire without any complications (Figure 2C). Neonates and infants with severe diseases often experience nutrition difficulties. The use of naso-gastric or, in case of gastric emptying disorders, post-pyloric tubes may be necessary.1 Blind bedside placement of duodenal tubes can be challenging.2 Endoscopic or percutaneous approaches are alternative, but invasive techniques. Derived from conventional cardiovascular catheterization using angiography catheters under brief fluoroscopy, the over-the-wire technique is a simple method for the safe and correct placement of duodenal tubes.3, 4 Open Access funding enabled and organized by Projekt DEAL. The authors declare no conflicts of interest. Written informed consent was obtained from the patient's father for publication of the images, and any potentially identifying information has been removed.

Authors

Institutions

Publication Details

Journal
JPGN Reports
Published
2025-11-27
DOI
https://doi.org/10.1002/jpr3.70122
Primary Topic
Clinical Nutrition and Gastroenterology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Over‐the‐wire insertion of a naso‐duodenal feeding tube in a critically ill infant

Jochen Pfeifer, Hashim Abdul‐Khaliq
JPGN Reports
Clinical Nutrition and Gastroenterology
article

Over‐the‐wire insertion of a naso‐duodenal feeding tube in a critically ill infant

Jochen Pfeifer, Hashim Abdul‐Khaliq
article en

Abstract

In a 7-month-old boy (body weight 7 kg) with congenital heart disease, short bowel syndrome, and gastric motility disorder, conventional insertion of a duodenal feeding tube was unsuccessful (Figure 1). Alternatively, a catheter-based method under fluoroscopy was performed. An angiography catheter (4F multipurpose special; Cordis Corp., Miami Lakes, FL, USA) was inserted nasogastrically into the stomach, then a guide wire (0.014'' Whisper™ ES; Abbott Medical, Santa Clara, CA, USA) was advanced into the duodenum over which the catheter could be pushed (Figure 2A). The course of the duodenum then was visualized by manual contrast injection (Figure 2B). Next, a more stable guide wire (0.018'' Nitrex™; ev3 Inc., Plymouth, MN, USA) was carefully inserted into the distal duodenum. To enable an insertion over-the-wire, the closed tip of an enteral feeding tube (8 F Freka™ Tube; Fresenius Kabi AG, Bad Homburg, Germany) was cut off. To deburr it, the tip was ground down and washed. Using ultrasound gel to improve gliding ability, the tube could be easily advanced into the duodenum via the wire without any complications (Figure 2C). Neonates and infants with severe diseases often experience nutrition difficulties. The use of naso-gastric or, in case of gastric emptying disorders, post-pyloric tubes may be necessary.1 Blind bedside placement of duodenal tubes can be challenging.2 Endoscopic or percutaneous approaches are alternative, but invasive techniques. Derived from conventional cardiovascular catheterization using angiography catheters under brief fluoroscopy, the over-the-wire technique is a simple method for the safe and correct placement of duodenal tubes.3, 4 Open Access funding enabled and organized by Projekt DEAL. The authors declare no conflicts of interest. Written informed consent was obtained from the patient's father for publication of the images, and any potentially identifying information has been removed.

JPGN ReportsVol. 7(1)
Saarland University (DE)
Openalex Percentile: Top 56%
Clinical Nutrition and Gastroenterology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Over‐the‐wire insertion of a naso‐duodenal feeding tube in a critically ill infant — Jochen Pfeifer, Hashim Abdul‐Khaliq · JPGN Reports (2025) | TGRS Research Map | TGRS