Fatigue performance of high-strength low-alloy DED-Arc components with Zn + Al2O3 low-pressure cold spray coating

Abstract Additive manufacturing using the directed energy deposition-arc (DED-Arc) process enables the production of customized structural components from high-strength low-alloy (HSLA) steels. The layer-wise deposition results in surface waviness, which affects the as-built components’ fatigue resistance. Additionally, the HSLA steel requires reliable corrosion protection for use in structural applications. This study investigates the applicability of low-pressure cold spray (LPCS) Zn + Al 2 O 3 coatings on as-built HSLA DED-Arc components with regard to fatigue performance and corrosion resistance. Multiple thin-walled components were manufactured using two different DED-Arc parameter sets, resulting in varying surface topographies. Selected components were coated with LPCS Zn + Al 2 O 3 , and a subset of those was subjected to cyclic corrosion testing (CCT). From the thin-walled components, several sets of fatigue specimens were extracted in deposition direction and geometrically characterized using 3D scanning, before and after CCT. Surface height parameters and volumetric geometry were analyzed, followed by uniaxial fatigue testing (stress ratio R = 0.1), together with four-camera digital image correlation (DIC) measurements of displacements at selected load cycles. The LPCS process enabled successful coating deposition with average Zn + Al 2 O 3 thicknesses of approx. 500 µm, and the CCT confirmed its effective cathodic corrosion protection for the DED-Arc HSLA material. Differences in surface topography and fatigue strength were observed depending on the applied DED-Arc process parameters, resulting in fatigue strengths ranging from FAT 80 to FAT 125. While LPCS Zn + Al 2 O 3 coating slightly increased surface height parameters, it did not affect fatigue strength compared to uncoated as-built components. Both the as-coated and corrosion-exposed conditions exhibited fatigue strength of FAT 125.

Authors

Institutions

Publication Details

Journal
Welding in the World
Published
2025-11-26
DOI
https://doi.org/10.1007/s40194-025-02262-5
Primary Topic
High-Temperature Coating Behaviors
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fatigue performance of high-strength low-alloy DED-Arc components with Zn + Al2O3 low-pressure cold spray coating

Julian Unglaub, Hendrik Jahns, Klaus Thiele, Heli Koivuluoto et al.
Welding in the World
High-Temperature Coating Behaviors
article

Fatigue performance of high-strength low-alloy DED-Arc components with Zn + Al2O3 low-pressure cold spray coating

Julian Unglaub, Hendrik Jahns, Klaus Thiele, Heli Koivuluoto, Suraj Panicker, Jonas Hensel, Hossein Mokhtarian, Martín Altobelli, Reza Jafari, Marc Müggenburg, Stefan Vogts
article en

Abstract

Abstract Additive manufacturing using the directed energy deposition-arc (DED-Arc) process enables the production of customized structural components from high-strength low-alloy (HSLA) steels. The layer-wise deposition results in surface waviness, which affects the as-built components’ fatigue resistance. Additionally, the HSLA steel requires reliable corrosion protection for use in structural applications. This study investigates the applicability of low-pressure cold spray (LPCS) Zn + Al 2 O 3 coatings on as-built HSLA DED-Arc components with regard to fatigue performance and corrosion resistance. Multiple thin-walled components were manufactured using two different DED-Arc parameter sets, resulting in varying surface topographies. Selected components were coated with LPCS Zn + Al 2 O 3 , and a subset of those was subjected to cyclic corrosion testing (CCT). From the thin-walled components, several sets of fatigue specimens were extracted in deposition direction and geometrically characterized using 3D scanning, before and after CCT. Surface height parameters and volumetric geometry were analyzed, followed by uniaxial fatigue testing (stress ratio R = 0.1), together with four-camera digital image correlation (DIC) measurements of displacements at selected load cycles. The LPCS process enabled successful coating deposition with average Zn + Al 2 O 3 thicknesses of approx. 500 µm, and the CCT confirmed its effective cathodic corrosion protection for the DED-Arc HSLA material. Differences in surface topography and fatigue strength were observed depending on the applied DED-Arc process parameters, resulting in fatigue strengths ranging from FAT 80 to FAT 125. While LPCS Zn + Al 2 O 3 coating slightly increased surface height parameters, it did not affect fatigue strength compared to uncoated as-built components. Both the as-coated and corrosion-exposed conditions exhibited fatigue strength of FAT 125.

Welding in the World
Tampere University (FI), Chemnitz University of Technology (DE), Technische Universität Braunschweig (DE)
Deutsche Forschungsgemeinschaft
Openalex Percentile: Top 53%
High-Temperature Coating Behaviors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.