Ultrasound urodynamic studies (US-UDS): noninvasive estimation of detrusor pressure through ultrasound

<i>Objective.</i>Urodynamic studies (UDSs) are vital for evaluating bladder function but require invasive catheterization to measure detrusor pressure (<i>P</i><sub>det</sub>). Our purpose is to report on technical developments toward a noninvasive and accurate estimation of<i>P</i><sub>det</sub>through ultrasound (US), a technique we refer to as US-UDS.<i>Approach.</i>The proposed US-UDS technique produces an estimate of<i>P</i><sub>det</sub>by using US to induce and track elastic waves that propagate within and around the bladder wall. Key components of the US-UDS processing include: an US sequence with dense time sampling; an empirical correction accounting for deviation from a Lamb wave dispersion model; and constrained optimization for<i>P</i><sub>det</sub>estimation. US-UDS analysis for estimation of<i>P</i><sub>det</sub>was applied to 533 distinct data points collected from 3 human subjects undergoing concurrent UDS. Concordance analysis was used to evaluate agreement between US-UDS and UDS measures of<i>P</i><sub>det</sub>while response operator characteristic analysis was used to evaluate US-UDS for detection of detrusor activity (parameterized as UDS<i>P</i><sub>det</sub>>15 cmH<sub>2</sub>O).<i>Main results.</i>US-UDS was able estimate<i>P</i><sub>det</sub>within 10 cmH<sub>2</sub>O and 5 cmH<sub>2</sub>O of UDS measurements with coverage probabilities of 95.7% and 68.8% respectively. Furthermore, US-UDS was able to detect UDS<i>P</i><sub>det</sub>measurements greater than 15 cmH<sub>2</sub>O with a sensitivities and specificities of 0.99 and 0.83 using a fixed threshold (>15 cmH<sub>2</sub>O for US-UDS) and 1.0 and 0.93 for an optimized threshold (> 11.08 cmH<sub>2</sub>O for US-UDS).<i>Significance.</i>Our results show that the technical developments of US-UDS put forth in this work are able produce accurate and useful estimates of<i>P</i><sub>det</sub>as compared to traditional UDS. Although additional research with a large number of subjects is needed to fully characterize the clinical utility of US-UDS, the developments and results from this work demonstrate that clinically useful non-invasive measurements of<i>P</i><sub>det</sub>are feasible from US measurements.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-11-14
DOI
https://doi.org/10.1088/1361-6560/ae1fcd
Primary Topic
Urinary Bladder and Prostate Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ultrasound urodynamic studies (US-UDS): noninvasive estimation of detrusor pressure through ultrasound

Brian J. Linder, Azra Alizad, David Rosen, Mostafa Fatemi
Physics in Medicine and Biology
Urinary Bladder and Prostate Research
article

Ultrasound urodynamic studies (US-UDS): noninvasive estimation of detrusor pressure through ultrasound

Brian J. Linder, Azra Alizad, David Rosen, Mostafa Fatemi
article en

Abstract

<i>Objective.</i>Urodynamic studies (UDSs) are vital for evaluating bladder function but require invasive catheterization to measure detrusor pressure (<i>P</i><sub>det</sub>). Our purpose is to report on technical developments toward a noninvasive and accurate estimation of<i>P</i><sub>det</sub>through ultrasound (US), a technique we refer to as US-UDS.<i>Approach.</i>The proposed US-UDS technique produces an estimate of<i>P</i><sub>det</sub>by using US to induce and track elastic waves that propagate within and around the bladder wall. Key components of the US-UDS processing include: an US sequence with dense time sampling; an empirical correction accounting for deviation from a Lamb wave dispersion model; and constrained optimization for<i>P</i><sub>det</sub>estimation. US-UDS analysis for estimation of<i>P</i><sub>det</sub>was applied to 533 distinct data points collected from 3 human subjects undergoing concurrent UDS. Concordance analysis was used to evaluate agreement between US-UDS and UDS measures of<i>P</i><sub>det</sub>while response operator characteristic analysis was used to evaluate US-UDS for detection of detrusor activity (parameterized as UDS<i>P</i><sub>det</sub>>15 cmH<sub>2</sub>O).<i>Main results.</i>US-UDS was able estimate<i>P</i><sub>det</sub>within 10 cmH<sub>2</sub>O and 5 cmH<sub>2</sub>O of UDS measurements with coverage probabilities of 95.7% and 68.8% respectively. Furthermore, US-UDS was able to detect UDS<i>P</i><sub>det</sub>measurements greater than 15 cmH<sub>2</sub>O with a sensitivities and specificities of 0.99 and 0.83 using a fixed threshold (>15 cmH<sub>2</sub>O for US-UDS) and 1.0 and 0.93 for an optimized threshold (> 11.08 cmH<sub>2</sub>O for US-UDS).<i>Significance.</i>Our results show that the technical developments of US-UDS put forth in this work are able produce accurate and useful estimates of<i>P</i><sub>det</sub>as compared to traditional UDS. Although additional research with a large number of subjects is needed to fully characterize the clinical utility of US-UDS, the developments and results from this work demonstrate that clinically useful non-invasive measurements of<i>P</i><sub>det</sub>are feasible from US measurements.

Physics in Medicine and BiologyVol. 70(23)
Mayo Clinic (US), Mayo Clinic in Arizona (US), Mayo Clinic in Florida (US)
Openalex Percentile: Top 49%
Urinary Bladder and Prostate Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.