Experiment and exergy analysis on performance of plate-fin heat exchanger with transient frosting process

In engineering applications, the plate-fin heat exchanger is selected in a preferential manner owing to its high heat transfer coefficient and compactness. When the temperature of plate-fin heat exchanger is lower than the triple point temperature, frosting process might appear on the cold surface of the heat exchanger channel. The accumulation of frost mass in the flow channel leads to higher thermal and flow resistance in the heat exchanger. To retard or alleviates the adverse effect of frost, the transient frosting process inside the flow channel of plate-fin heat exchanger are researched experimentally in this paper. The influencing extent of environmental factors on the transient frosting process of the heat exchanger are investigated. The operating conditions and influencing factors of experiments are designed by orthogonal tables. The influencing factors are evaluated by analysis of variance (ANOVA) and range analysis. The experimental and analytical results showed that the maximum frosting rate is mainly affected by the flow rate and humidity content of humidified warm nitrogen. With higher flow rate and humidity content of humidified warm nitrogen, both flow resistance and heat transfer resistance rise with frosting process. Larger frost mass enlarges the pressure difference between inlet and outlet of humidified warm nitrogen. Furthermore, exergy efficiency of plate-fin heat exchanger deteriorates significantly with the accumulation of frost mass. • Transient frosting on plate-fin heat exchanger performance is experimentally studied. • The influencing extent of factors is evaluated by orthogonal experiment and analysis. • Heat flux and pressure drop in heat exchanger are studied under various frost cases. • Transient process of heat exchanger exergy efficiency is analyzed with frosting.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2025-11-26
DOI
https://doi.org/10.1016/j.csite.2025.107461
Primary Topic
Heat Transfer and Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Experiment and exergy analysis on performance of plate-fin heat exchanger with transient frosting process

Shaohang Yan, Tianwei Lai, Xiaojun Dong, Yu Hou et al.
Case Studies in Thermal Engineering
Heat Transfer and Optimization
article

Experiment and exergy analysis on performance of plate-fin heat exchanger with transient frosting process

Shaohang Yan, Tianwei Lai, Xiaojun Dong, Yu Hou, Feng‐Yang Zhang, Zhen Wang
article en

Abstract

In engineering applications, the plate-fin heat exchanger is selected in a preferential manner owing to its high heat transfer coefficient and compactness. When the temperature of plate-fin heat exchanger is lower than the triple point temperature, frosting process might appear on the cold surface of the heat exchanger channel. The accumulation of frost mass in the flow channel leads to higher thermal and flow resistance in the heat exchanger. To retard or alleviates the adverse effect of frost, the transient frosting process inside the flow channel of plate-fin heat exchanger are researched experimentally in this paper. The influencing extent of environmental factors on the transient frosting process of the heat exchanger are investigated. The operating conditions and influencing factors of experiments are designed by orthogonal tables. The influencing factors are evaluated by analysis of variance (ANOVA) and range analysis. The experimental and analytical results showed that the maximum frosting rate is mainly affected by the flow rate and humidity content of humidified warm nitrogen. With higher flow rate and humidity content of humidified warm nitrogen, both flow resistance and heat transfer resistance rise with frosting process. Larger frost mass enlarges the pressure difference between inlet and outlet of humidified warm nitrogen. Furthermore, exergy efficiency of plate-fin heat exchanger deteriorates significantly with the accumulation of frost mass. • Transient frosting on plate-fin heat exchanger performance is experimentally studied. • The influencing extent of factors is evaluated by orthogonal experiment and analysis. • Heat flux and pressure drop in heat exchanger are studied under various frost cases. • Transient process of heat exchanger exergy efficiency is analyzed with frosting.

Case Studies in Thermal EngineeringVol. 76
Xi'an Jiaotong University (CN)
Openalex Percentile: Top 62%
Heat Transfer and Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.