Nonspecific protein absorption is an ongoing problem in the development of highly sensitive magnetic particle (MP)-based diagnostic assays, whereby the MP surface undergoes biofouling, significantly reducing the limit of detection and sensitivity of the device. In this study, a bioinert, concentrated polymer brush (CPB) composed of poly[poly(ethylene oxide) methyl ether methacrylate] (PPEGMA) was employed to reduce the absorption of protein onto the MP surfaces; and an anti-human serum albumin antibody (Ab) was then immobilized onto the brush layer by click chemistry to demonstrate its application as an immunoassay platform. The amount of antibody grafted onto the ends of the brush coating was quantified by a BCA assay with a high grafting efficiency (∼0.80 antibody per chain). Furthermore, when using the antibody-conjugated CPB-coated MPs (MP-PPEGMA-Ab) as an immunoassay platform, we were able to determine the capture efficacy of human serum albumin (HSA) in both a buffered solution and diluted human serum by colorimetric analysis, and further confirmation was achieved via liquid chromatography/mass spectrometry, in which our MPs showed a high selectivity toward the targeted analyte. Lastly, we demonstrated that MP-PPEGMA-Ab was capable of detecting human serum albumin at a concentration as low as 6.4 ng mL<sup>-1</sup>, 30% more sensitive than the unmodified MP, demonstrating the impact of CPBs on diagnostic assays. Due to their high selectivity and sensitivity, our CPB-based MPs are expected to be applicable for a wide range of immunoassay applications by employing different bioinert polymers and biofunctional groups.

Authors

Institutions

Publication Details

Journal
Langmuir
Published
2025-11-25
DOI
https://doi.org/10.1021/acs.langmuir.5c04175
Citations
1
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Concentrated Polymer Brush-Modified Magnetic Particles for a Diagnostic Immunoassay

E. Bosch, Jun Qiu, Chiaki Yoshikawa, Gabriel T. Huynh et al.
1 citations
Langmuir
Biosensors and Analytical Detection
0.67
article

Concentrated Polymer Brush-Modified Magnetic Particles for a Diagnostic Immunoassay

E. Bosch, Jun Qiu, Chiaki Yoshikawa, Gabriel T. Huynh, Tomohiko Yamazaki
article en
1 citations

Abstract

Nonspecific protein absorption is an ongoing problem in the development of highly sensitive magnetic particle (MP)-based diagnostic assays, whereby the MP surface undergoes biofouling, significantly reducing the limit of detection and sensitivity of the device. In this study, a bioinert, concentrated polymer brush (CPB) composed of poly[poly(ethylene oxide) methyl ether methacrylate] (PPEGMA) was employed to reduce the absorption of protein onto the MP surfaces; and an anti-human serum albumin antibody (Ab) was then immobilized onto the brush layer by click chemistry to demonstrate its application as an immunoassay platform. The amount of antibody grafted onto the ends of the brush coating was quantified by a BCA assay with a high grafting efficiency (∼0.80 antibody per chain). Furthermore, when using the antibody-conjugated CPB-coated MPs (MP-PPEGMA-Ab) as an immunoassay platform, we were able to determine the capture efficacy of human serum albumin (HSA) in both a buffered solution and diluted human serum by colorimetric analysis, and further confirmation was achieved via liquid chromatography/mass spectrometry, in which our MPs showed a high selectivity toward the targeted analyte. Lastly, we demonstrated that MP-PPEGMA-Ab was capable of detecting human serum albumin at a concentration as low as 6.4 ng mL<sup>-1</sup>, 30% more sensitive than the unmodified MP, demonstrating the impact of CPBs on diagnostic assays. Due to their high selectivity and sensitivity, our CPB-based MPs are expected to be applicable for a wide range of immunoassay applications by employing different bioinert polymers and biofunctional groups.

LangmuirVol. 41(48)
DSM (Netherlands) (NL), Hokkaido University (JP), National Institute for Materials Science (JP), Association on Higher Education And Disability (US)
Openalex Percentile: Top 24%
Biosensors and Analytical Detection
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.