Performance Prediction of a Vertical Downward Supply Direct Expansion Cooling System for Large Spaces Through Field Experiments

Performance prediction of an air-cooled direct expansion (DX) vertical downward-supply cooling system applied to large spaces is a key element for achieving efficient control and energy savings. Recent studies have predominantly relied on complex artificial intelligence (AI)-based or high-dimensional models that require a large number of input variables to achieve high predictive accuracy. In contrast, limited research has focused on developing simple, interpretable, and practically applicable models based on field-measured data. To address this gap, the present study proposes a physically grounded multiple linear regression model with a minimal number of variables, which can be implemented in practice using only three standard sensors: indoor air temperature, outdoor air temperature, and airflow rate. Field data were refined through physical criteria derived from ASHRAE standards (steady-state operation and removal of outliers) and by identifying steady-state ranges using the Kernel Density Estimation (KDE) method. A total of 133,718 valid samples were used for analysis. The proposed model achieved a coefficient of determination (R2) of 0.93, a root mean square error (RMSE) of 2.86 kW, and mean absolute error (MAE) of 2.31 kW, corresponding to approximately ±6% deviation from measured cooling capacity. These results satisfy the typical accuracy criteria in the HVAC field (R2 > 0.9, error < 10%) and confirm high predictive reliability despite the model’s simplicity. The achieved accuracy implies that the proposed model can be extended to field-level performance prediction and energy-efficient operation. Comparison with second-order polynomial and nonlinear (1/Tout) models showed only marginal improvement in accuracy. Consequently, the proposed three-variable regression model introduces a practical framework for performance prediction and control of DX-type cooling systems that integrates simplicity, physical interpretability, and field applicability.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-11-24
DOI
https://doi.org/10.3390/en18236160
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Performance Prediction of a Vertical Downward Supply Direct Expansion Cooling System for Large Spaces Through Field Experiments

Young Il Kim, Tai Min
Energies
Adsorption and Cooling Systems
article

Performance Prediction of a Vertical Downward Supply Direct Expansion Cooling System for Large Spaces Through Field Experiments

Young Il Kim, Tai Min
article en

Abstract

Performance prediction of an air-cooled direct expansion (DX) vertical downward-supply cooling system applied to large spaces is a key element for achieving efficient control and energy savings. Recent studies have predominantly relied on complex artificial intelligence (AI)-based or high-dimensional models that require a large number of input variables to achieve high predictive accuracy. In contrast, limited research has focused on developing simple, interpretable, and practically applicable models based on field-measured data. To address this gap, the present study proposes a physically grounded multiple linear regression model with a minimal number of variables, which can be implemented in practice using only three standard sensors: indoor air temperature, outdoor air temperature, and airflow rate. Field data were refined through physical criteria derived from ASHRAE standards (steady-state operation and removal of outliers) and by identifying steady-state ranges using the Kernel Density Estimation (KDE) method. A total of 133,718 valid samples were used for analysis. The proposed model achieved a coefficient of determination (R2) of 0.93, a root mean square error (RMSE) of 2.86 kW, and mean absolute error (MAE) of 2.31 kW, corresponding to approximately ±6% deviation from measured cooling capacity. These results satisfy the typical accuracy criteria in the HVAC field (R2 > 0.9, error < 10%) and confirm high predictive reliability despite the model’s simplicity. The achieved accuracy implies that the proposed model can be extended to field-level performance prediction and energy-efficient operation. Comparison with second-order polynomial and nonlinear (1/Tout) models showed only marginal improvement in accuracy. Consequently, the proposed three-variable regression model introduces a practical framework for performance prediction and control of DX-type cooling systems that integrates simplicity, physical interpretability, and field applicability.

EnergiesVol. 18(23)
Seoul National University of Science and Technology (KR)
Openalex Percentile: Top 62%
Adsorption and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.