Size Effects of Silver Nanoparticles and Magnetic Beads on Silver-Gold Galvanic Exchange in Aptamer-Based Electrochemical Assays

In this work, we investigated the influence of silver nanoparticle (AgNP) size (diameters of 20, 50, and 100 nm) and magnetic bead (MB) size (diameters from 100 to 4500 nm) on silver-gold galvanic exchange signal generation in magnetic electrochemical assays. Two conjugation strategies, including biotin-streptavidin interaction and a streptavidin-specific aptamer interaction, were compared to assess differences in binding chemistry and conjugation efficiency. Calibration studies showed that 50 nm diameter AgNPs provided the best sensitivity and galvanic exchange efficiency, yielding the lowest detection limits across both conjugation strategies. Larger AgNPs produced stronger signals but reached saturation rapidly, whereas smaller particles required higher concentrations to achieve equivalent silver content. Among MBs, 1000 nm beads consistently gave the highest galvanic exchange efficiency, offering sufficient surface area for AgNP loading while minimizing steric hindrance and electrode obstruction. These findings were confirmed by complementary electrochemical impedance spectroscopy, UV-Vis absorbance, and SEM imaging, which collectively demonstrated the strong influence of bead size on charge transfer resistance and conjugation efficiency. Overall, the combination of 50 nm AgNPs with 1000 nm MBs emerged as the optimal configuration, providing improved sensitivity and reproducibility. We believe these results offer valuable design guidelines for the development of next-generation aptamer-based electrochemical biosensors for biomarker detection.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2025-11-25
DOI
https://doi.org/10.3390/bios15120768
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Size Effects of Silver Nanoparticles and Magnetic Beads on Silver-Gold Galvanic Exchange in Aptamer-Based Electrochemical Assays

Charuksha Walgama, Daniel Adrian, Trang Bui, Marco Cardenas et al.
Biosensors
Advanced biosensing and bioanalysis techniques
article

Size Effects of Silver Nanoparticles and Magnetic Beads on Silver-Gold Galvanic Exchange in Aptamer-Based Electrochemical Assays

Charuksha Walgama, Daniel Adrian, Trang Bui, Marco Cardenas, Eman Alwarsh
article en

Abstract

In this work, we investigated the influence of silver nanoparticle (AgNP) size (diameters of 20, 50, and 100 nm) and magnetic bead (MB) size (diameters from 100 to 4500 nm) on silver-gold galvanic exchange signal generation in magnetic electrochemical assays. Two conjugation strategies, including biotin-streptavidin interaction and a streptavidin-specific aptamer interaction, were compared to assess differences in binding chemistry and conjugation efficiency. Calibration studies showed that 50 nm diameter AgNPs provided the best sensitivity and galvanic exchange efficiency, yielding the lowest detection limits across both conjugation strategies. Larger AgNPs produced stronger signals but reached saturation rapidly, whereas smaller particles required higher concentrations to achieve equivalent silver content. Among MBs, 1000 nm beads consistently gave the highest galvanic exchange efficiency, offering sufficient surface area for AgNP loading while minimizing steric hindrance and electrode obstruction. These findings were confirmed by complementary electrochemical impedance spectroscopy, UV-Vis absorbance, and SEM imaging, which collectively demonstrated the strong influence of bead size on charge transfer resistance and conjugation efficiency. Overall, the combination of 50 nm AgNPs with 1000 nm MBs emerged as the optimal configuration, providing improved sensitivity and reproducibility. We believe these results offer valuable design guidelines for the development of next-generation aptamer-based electrochemical biosensors for biomarker detection.

BiosensorsVol. 15(12)
University of Houston - Clear Lake (US)
U.S. Department of Education
Openalex Percentile: Top 67%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.