Implantable Knitted Fabric Structured Electrode for Monitoring and Treatment of Cardiac Arrhythmias

Abstract Arrhythmia is one of the most common complications during open‐heart surgery and poses a serious threat to patient safety if not promptly treated. However, most recently developed implantable electrocardiogram sensors for arrhythmia monitoring and treatment adopt 2D thin‐film structures, which are non‐breathable and hinder metabolic exchange processes at the cardiac surface. Here, a highly breathable and mechanically adaptive knitted fabric structured cardiac electrode for real‐time arrhythmia monitoring and radiofrequency ablation therapy is reported. The electrode is fabricated from nylon fibers coated with gold‐shelled silver nanowires via computer‐controlled flat knitting techniques. This knitted structure has an ultralow Young's modulus (9.31 kPa), significantly minimizing mechanical interference with cardiac motion. Moreover, the electrode passively stretches during diastole and actively retightens during systole, dynamically conforming to the beating heart, allowing for stable monitoring of the heart's surface for 12 h. The use of nanowires imparts excellent electrical properties, with the electrode impedance being only ≈1/3 that of dense silver wires at 1000 Hz, enabling high‐fidelity signal recording and low‐voltage ablation. Moreover, the electrode retains stable electrical performance after 500 000 cycles of dynamic strain. In vivo biocompatibility tests validate the safety of the device. In a mouse model, the electrode successfully localizes the origin of abnormal electrical signals during atrial fibrillation and guides effective radiofrequency ablation to restore sinus rhythm, demonstrating strong potential for clinical translation.

Authors

Institutions

Publication Details

Journal
Advanced Functional Materials
Published
2025-11-26
DOI
https://doi.org/10.1002/adfm.202512103
Primary Topic
Advanced Sensor and Energy Harvesting Materials
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implantable Knitted Fabric Structured Electrode for Monitoring and Treatment of Cardiac Arrhythmias

Xiao Jun Sun, Sijia Yu, Liyuan Wang, Wei He et al.
Advanced Functional Materials
Advanced Sensor and Energy Harvesting Materials
article

Implantable Knitted Fabric Structured Electrode for Monitoring and Treatment of Cardiac Arrhythmias

Xiao Jun Sun, Sijia Yu, Liyuan Wang, Wei He, Songlin Zhang, Yiqing Yang, Huisheng Peng, Hang Guan, Lingsen You, Chengqiang Tang
article en

Abstract

Abstract Arrhythmia is one of the most common complications during open‐heart surgery and poses a serious threat to patient safety if not promptly treated. However, most recently developed implantable electrocardiogram sensors for arrhythmia monitoring and treatment adopt 2D thin‐film structures, which are non‐breathable and hinder metabolic exchange processes at the cardiac surface. Here, a highly breathable and mechanically adaptive knitted fabric structured cardiac electrode for real‐time arrhythmia monitoring and radiofrequency ablation therapy is reported. The electrode is fabricated from nylon fibers coated with gold‐shelled silver nanowires via computer‐controlled flat knitting techniques. This knitted structure has an ultralow Young's modulus (9.31 kPa), significantly minimizing mechanical interference with cardiac motion. Moreover, the electrode passively stretches during diastole and actively retightens during systole, dynamically conforming to the beating heart, allowing for stable monitoring of the heart's surface for 12 h. The use of nanowires imparts excellent electrical properties, with the electrode impedance being only ≈1/3 that of dense silver wires at 1000 Hz, enabling high‐fidelity signal recording and low‐voltage ablation. Moreover, the electrode retains stable electrical performance after 500 000 cycles of dynamic strain. In vivo biocompatibility tests validate the safety of the device. In a mouse model, the electrode successfully localizes the origin of abnormal electrical signals during atrial fibrillation and guides effective radiofrequency ablation to restore sinus rhythm, demonstrating strong potential for clinical translation.

Advanced Functional MaterialsVol. 35(50)
Central South University (CN), Fudan University (CN), Zhongshan Hospital (CN), Children's Hospital of Fudan University (CN), Xiangya Hospital Central South University (CN)
Openalex Percentile: Top 64%
Advanced Sensor and Energy Harvesting Materials
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.