Using steel mesh as internal reinforcement in the concrete supports subjected to partially compressive load

Certain concrete components, such corbels, column-footing joints, and post-tensioning prestressed parts, require the load to be transferred from a small region to a broad area. The behavior of the concrete under the impact of local bearing load must be studied in order to transfer the load between concrete pieces securely. The interior core of the concrete supports that are partially compressed is contained by means of steel mesh fabric (SMF) reinforcement in this study. Fifteen concrete blocks were constructed and subsequently subjected to local bearing loads by a steel plate with various areas. SMFs shaped like a box and a cylinder were used as internal reinforcement in the concrete core of the block samples. These SMF patterns varied in volume ratio (V = 0 to 0.4%), form (box or cylinder), and height (h = 0.5 and 1 of block height). Failure mechanisms, bearing stress-slip curve, initial fracture load, ductility, bearing stiffness, ultimate bearing strength, and ultimate corresponding slip of the bearing plate were all discussed for the samples under examination. The first fracture stress of the SMF-reinforced block samples was 30-180% greater than that of the unreinforced sample, according to the results. SMF-samples' bearing stiffness was unaffected. The bearing strength, related slip, and ductility were 45%, 88%, and 118% and 42%, 90%, and 99% and 102%, 123%, and 167% greater than those of the control sample when box SMF with lengths of 1, 2, and 2.6 times the bearing plate area was used. Changing the height of the SMF has only a little effect on the bearing strength ratings of the concrete blocks.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-11-26
DOI
https://doi.org/10.1038/s41598-025-26266-9
Primary Topic
Structural Behavior of Reinforced Concrete
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Using steel mesh as internal reinforcement in the concrete supports subjected to partially compressive load

Mohammed K. Alkharisi, Ahmed Bayoumi, Md. Habibur Rahman Sobuz, Ahmed Hamoda et al.
Scientific Reports
Structural Behavior of Reinforced Concrete
article

Using steel mesh as internal reinforcement in the concrete supports subjected to partially compressive load

Mohammed K. Alkharisi, Ahmed Bayoumi, Md. Habibur Rahman Sobuz, Ahmed Hamoda, Sabry Fayed, Mohamed Ghalla, Basant ahmed Ramadan, Sani Aliyu Abubakar
article en

Abstract

Certain concrete components, such corbels, column-footing joints, and post-tensioning prestressed parts, require the load to be transferred from a small region to a broad area. The behavior of the concrete under the impact of local bearing load must be studied in order to transfer the load between concrete pieces securely. The interior core of the concrete supports that are partially compressed is contained by means of steel mesh fabric (SMF) reinforcement in this study. Fifteen concrete blocks were constructed and subsequently subjected to local bearing loads by a steel plate with various areas. SMFs shaped like a box and a cylinder were used as internal reinforcement in the concrete core of the block samples. These SMF patterns varied in volume ratio (V = 0 to 0.4%), form (box or cylinder), and height (h = 0.5 and 1 of block height). Failure mechanisms, bearing stress-slip curve, initial fracture load, ductility, bearing stiffness, ultimate bearing strength, and ultimate corresponding slip of the bearing plate were all discussed for the samples under examination. The first fracture stress of the SMF-reinforced block samples was 30-180% greater than that of the unreinforced sample, according to the results. SMF-samples' bearing stiffness was unaffected. The bearing strength, related slip, and ductility were 45%, 88%, and 118% and 42%, 90%, and 99% and 102%, 123%, and 167% greater than those of the control sample when box SMF with lengths of 1, 2, and 2.6 times the bearing plate area was used. Changing the height of the SMF has only a little effect on the bearing strength ratings of the concrete blocks.

Scientific ReportsVol. 15(1)
Kafrelsheikh University (EG), Khulna University of Engineering and Technology (BD), Qassim University (SA), Kampala International University (UG), Ministry of Communication and Information Technology (ET), Ministry of Justice (HR), Higher Institute of Engineering (EG), Ministry of Justice (JP)
Openalex Percentile: Top 61%
Structural Behavior of Reinforced Concrete
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.