Patient–Ventilator Interaction During Noninvasive Ventilation

Patient-ventilator discordance commonly occurs in patients receiving noninvasive ventilation (NIV). Unintentional leaks contribute to trigger and cycle asynchrony. Historically, ventilators designed for NIV with an intentional leak circuit compensated for unintentional leaks better than critical care ventilators. However, many critical care ventilators now have NIV settings for leak compensation. Per bench studies and some clinical studies, NIV settings for leak compensation variably improve synchrony related to leak. Some interfaces, such as the helmet, can contribute to asynchrony. Ventilator modes such a neurally adjusted ventilatory assist might improve synchrony but might not lead to better patient outcomes. Adaptive pressure control modes have the potential to remove support with increased patient effort, resulting in work shifting from the ventilator to the patient. Moreover, these modes are complicated if the ventilator does not correctly estimate tidal volume during NIV. Adding flow to the circuit, such as adding oxygen to increase F<sub>IO<sub>2</sub></sub>, can also contribute to asynchrony. This article addresses issues related to discordance with NIV and strategies to improve patient-ventilator interactions during NIV.

Authors

Institutions

Publication Details

Journal
Respiratory Care
Published
2025-11-26
DOI
https://doi.org/10.1177/19433654251391165
Primary Topic
Respiratory Support and Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Patient–Ventilator Interaction During Noninvasive Ventilation

Dean Hess
Respiratory Care
Respiratory Support and Mechanisms
article

Patient–Ventilator Interaction During Noninvasive Ventilation

Dean Hess
article en

Abstract

Patient-ventilator discordance commonly occurs in patients receiving noninvasive ventilation (NIV). Unintentional leaks contribute to trigger and cycle asynchrony. Historically, ventilators designed for NIV with an intentional leak circuit compensated for unintentional leaks better than critical care ventilators. However, many critical care ventilators now have NIV settings for leak compensation. Per bench studies and some clinical studies, NIV settings for leak compensation variably improve synchrony related to leak. Some interfaces, such as the helmet, can contribute to asynchrony. Ventilator modes such a neurally adjusted ventilatory assist might improve synchrony but might not lead to better patient outcomes. Adaptive pressure control modes have the potential to remove support with increased patient effort, resulting in work shifting from the ventilator to the patient. Moreover, these modes are complicated if the ventilator does not correctly estimate tidal volume during NIV. Adding flow to the circuit, such as adding oxygen to increase F<sub>IO<sub>2</sub></sub>, can also contribute to asynchrony. This article addresses issues related to discordance with NIV and strategies to improve patient-ventilator interactions during NIV.

Respiratory Care
ET Enterprises (United Kingdom) (GB)
Openalex Percentile: Top 45%
Respiratory Support and Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.