Comparative Study of Structural Designs of Stationary Components in Ultra-High-Head Pumped Storage Units

Pumped storage power stations provide essential benefits to power grids by cutting peak loads, filling valleys, and boosting renewable energy integration rates. They serve as the foundation for developing a new power system based on renewable energy. Pump turbines are currently evolving to provide higher heads, larger capacities, and higher rotating speeds. The performance and dependability of its basic components have a direct impact on the safety and stability of unit operation. Based on this, this research looks into the modal characteristics and structural aspects of essential stationary components, such as the pump-turbine head cover. By comparing the mechanical performance of two different structural designs (Design A and Design B), Design B features an overall thickness 1.5 times that of Design A and incorporates an upper flange structure. Its design aims to enhance the component’s resistance to bending and deformation, optimize stress distribution while reducing peak stress values, and improve modal characteristics. This approach elevates the overall structural performance of the fixed components to accommodate the complex operating conditions of ultra-high-head pumped storage units. It was discovered that Design B had greater bending and deformation resistance than Design A, as well as better stress distribution and lower maximum stress values. This study further indicates that variations in structural design lead to significant differences in modal characteristics and overall structural performance. In particular, the thicknesses of the head cover’s main body and stiffening ribs are critical parameters that govern the modal behavior and structural properties of stationary components. These insights provide critical technical guidance for optimizing the design of stationary parts, such as the head cover, in pumped storage power plant units.

Authors

Institutions

Publication Details

Journal
Processes
Published
2025-11-26
DOI
https://doi.org/10.3390/pr13123826
Citations
1
Primary Topic
Cavitation Phenomena in Pumps
Type
article
Field-Weighted Citation Impact
0.86
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Study of Structural Designs of Stationary Components in Ultra-High-Head Pumped Storage Units

Meng Liu, Zhengwei Wang, Feng Jin, Jian Liu et al.
1 citations
Processes
Cavitation Phenomena in Pumps
0.86
article

Comparative Study of Structural Designs of Stationary Components in Ultra-High-Head Pumped Storage Units

Meng Liu, Zhengwei Wang, Feng Jin, Jian Liu, Xingxing Huang, Guoliang Cao, Dawei Zheng, Zebin Lai
article en
1 citations

Abstract

Pumped storage power stations provide essential benefits to power grids by cutting peak loads, filling valleys, and boosting renewable energy integration rates. They serve as the foundation for developing a new power system based on renewable energy. Pump turbines are currently evolving to provide higher heads, larger capacities, and higher rotating speeds. The performance and dependability of its basic components have a direct impact on the safety and stability of unit operation. Based on this, this research looks into the modal characteristics and structural aspects of essential stationary components, such as the pump-turbine head cover. By comparing the mechanical performance of two different structural designs (Design A and Design B), Design B features an overall thickness 1.5 times that of Design A and incorporates an upper flange structure. Its design aims to enhance the component’s resistance to bending and deformation, optimize stress distribution while reducing peak stress values, and improve modal characteristics. This approach elevates the overall structural performance of the fixed components to accommodate the complex operating conditions of ultra-high-head pumped storage units. It was discovered that Design B had greater bending and deformation resistance than Design A, as well as better stress distribution and lower maximum stress values. This study further indicates that variations in structural design lead to significant differences in modal characteristics and overall structural performance. In particular, the thicknesses of the head cover’s main body and stiffening ribs are critical parameters that govern the modal behavior and structural properties of stationary components. These insights provide critical technical guidance for optimizing the design of stationary parts, such as the head cover, in pumped storage power plant units.

ProcessesVol. 13(12)
Qinghai University (CN), State Grid Corporation of China (China) (CN), Swiss Federal Office of Energy (CH), Ministry of Water Resources of the People's Republic of China (CN), Yellow River Institute of Hydraulic Research (CN), Tsinghua University (CN)
Openalex Percentile: Top 22%
Cavitation Phenomena in Pumps
0.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.