3D Latent Diffusion Model for MR-Only Radiotherapy: Accurate and Consistent Synthetic CT Generation

<b>Background</b>: The clinical imperative to reduce patient ionizing radiation exposure during diagnosis and treatment planning necessitates robust, high-fidelity synthetic imaging solutions. Current cross-modal synthesis techniques, primarily based on GANs and deterministic CNNs, exhibit instability and critical errors in modeling high-contrast tissues, thereby hindering their reliability for safety-critical applications such as radiotherapy. Objectives: Our primary objective was to develop a stable, high accuracy framework for 3D Magnetic Resonance Imaging (MRI) to Computed Tomography (CT) synthesis capable of generating clinically equivalent synthetic CTs (sCTs) across multiple anatomical sites. <b>Methods:</b> We introduce a novel 3D Latent Diffusion Model (3DLDM) that operates in a compressed latent space, mitigating the computational burden of 3D diffusion while leveraging the stability of the denoising objective. <b>Results:</b> Across the Head & Neck, Thorax, and Abdomen, the 3DLDM achieved a Mean Absolute Error (MAE) of 56.44 Hounsfield Units (HU). This result demonstrates a significant 3.63% reduction in overall error compared to the strongest adversarial baseline, CycleGAN (MAE = 60.07 HU, <i>p</i> < 0.05), a 10.76% reduction compared to NNUNet (MAE = 67.20 HU, <i>p</i> < 0.01), and a 20.79% reduction compared to the transformer-based SwinUNeTr (MAE = 77.23 HU, <i>p</i> < 0.0001). The model also achieved the highest structural similarity (SSIM = 0.885 ± 0.031), significantly exceeding SwinUNeTr (<i>p</i> < 0.0001), NNUNet (<i>p</i> < 0.01), and Pix2Pix (<i>p</i> < 0.0001). Likewise, the 3D-LDM achieved the highest peak signal-to-noise ratio (PSNR = 29.73 ± 1.60 dB), with statistically significant gains over CycleGAN (<i>p</i> < 0.01), NNUNet (<i>p</i> < 0.001), and SwinUNeTr (<i>p</i> < 0.0001). <b>Conclusions:</b> This work validates a scalable, accurate approach for volumetric synthesis, positioning the 3DLDM to enable MR-only radiotherapy planning and accelerate radiation-free multi-modal imaging in the clinic.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2025-11-26
DOI
https://doi.org/10.3390/diagnostics15233010
Citations
1
Primary Topic
Radiomics and Machine Learning in Medical Imaging
Type
article
Field-Weighted Citation Impact
1.36
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

3D Latent Diffusion Model for MR-Only Radiotherapy: Accurate and Consistent Synthetic CT Generation

Mohammed Al-Shalabi, T. Alnfrawy Ehab, Mohammed A. Mahdi, Muhammad Usman Hadi et al.
1 citations
Diagnostics
Radiomics and Machine Learning in Medical Imaging
1.36
article

3D Latent Diffusion Model for MR-Only Radiotherapy: Accurate and Consistent Synthetic CT Generation

Mohammed Al-Shalabi, T. Alnfrawy Ehab, Mohammed A. Mahdi, Muhammad Usman Hadi, Rao Faizan Ali, Reda Elbarougy
article en
1 citations

Abstract

<b>Background</b>: The clinical imperative to reduce patient ionizing radiation exposure during diagnosis and treatment planning necessitates robust, high-fidelity synthetic imaging solutions. Current cross-modal synthesis techniques, primarily based on GANs and deterministic CNNs, exhibit instability and critical errors in modeling high-contrast tissues, thereby hindering their reliability for safety-critical applications such as radiotherapy. Objectives: Our primary objective was to develop a stable, high accuracy framework for 3D Magnetic Resonance Imaging (MRI) to Computed Tomography (CT) synthesis capable of generating clinically equivalent synthetic CTs (sCTs) across multiple anatomical sites. <b>Methods:</b> We introduce a novel 3D Latent Diffusion Model (3DLDM) that operates in a compressed latent space, mitigating the computational burden of 3D diffusion while leveraging the stability of the denoising objective. <b>Results:</b> Across the Head & Neck, Thorax, and Abdomen, the 3DLDM achieved a Mean Absolute Error (MAE) of 56.44 Hounsfield Units (HU). This result demonstrates a significant 3.63% reduction in overall error compared to the strongest adversarial baseline, CycleGAN (MAE = 60.07 HU, <i>p</i> < 0.05), a 10.76% reduction compared to NNUNet (MAE = 67.20 HU, <i>p</i> < 0.01), and a 20.79% reduction compared to the transformer-based SwinUNeTr (MAE = 77.23 HU, <i>p</i> < 0.0001). The model also achieved the highest structural similarity (SSIM = 0.885 ± 0.031), significantly exceeding SwinUNeTr (<i>p</i> < 0.0001), NNUNet (<i>p</i> < 0.01), and Pix2Pix (<i>p</i> < 0.0001). Likewise, the 3D-LDM achieved the highest peak signal-to-noise ratio (PSNR = 29.73 ± 1.60 dB), with statistically significant gains over CycleGAN (<i>p</i> < 0.01), NNUNet (<i>p</i> < 0.001), and SwinUNeTr (<i>p</i> < 0.0001). <b>Conclusions:</b> This work validates a scalable, accurate approach for volumetric synthesis, positioning the 3DLDM to enable MR-only radiotherapy planning and accelerate radiation-free multi-modal imaging in the clinic.

DiagnosticsVol. 15(23)
University of Ulster (GB), University of Kent (GB), University of Ha'il (SA)
Openalex Percentile: Top 14%
Radiomics and Machine Learning in Medical Imaging
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.