Assessment of reliability and concurrent validity of a single trunk-based IMU system to quantify spatiotemporal parameters in healthy individuals

Commercially available Inertial Measurement Units (IMU) are gaining popularity in clinical gait analysis. Compared to standard optoelectronic motion capture systems (OMCs), IMUs offer advantages such as lower cost, greater time efficiency, and the ability to be used outside of laboratory settings. IMUs can be attached to various body parts and have already been tested in numerous clinical studies. This study aimed to assess the intra-session reliability and concurrent validity of a trunk-based IMU system (BTS G-Walk®) in healthy individuals compared to an OMC system (VICON®). To test the intra-session reliability and concurrent validity of the BTS-G-Walk®, 27 healthy participants were recruited for gait analysis. Both the IMU and OMC systems were used simultaneously to record spatiotemporal gait parameters under a standardized laboratory protocol. Eight spatiotemporal parameters were analyzed, using the Intraclass Correlation Coefficient (ICC 2,k) and Bland–Altman analysis to evaluate the reliability and concurrent validity. The IMU demonstrated excellent intra-session reliability across all parameters (ICC: 0.952–0.995). Concurrent validity was good to excellent for cadence, speed, stride length, and stride duration (ICC: 0.807–0.999), but poor for stance phase, single support, double support, and swing phase (ICC: 0.036–0.136). Bland–Altman analysis showed the lowest mean percentage bias for cadence (− 0.18%) and the highest for double support phase (23.45%). The BTS-G-Walk® delivers reliable values in healthy individuals. Regarding concurrent validity, stride duration and cadence demonstrated the highest agreement with the reference system. Caution is advised when using the IMU in clinical practice, particularly for interpreting parameters dependent on toe-off events, such as gait phase durations.

Authors

Institutions

Publication Details

Journal
BMC Sports Science Medicine and Rehabilitation
Published
2025-11-26
DOI
https://doi.org/10.1186/s13102-025-01410-0
Primary Topic
Balance, Gait, and Falls Prevention
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of reliability and concurrent validity of a single trunk-based IMU system to quantify spatiotemporal parameters in healthy individuals

Bernhard Dumphart, Dieter H. Pahr, U. Ernst, Andrea Zauner-Dungl et al.
BMC Sports Science Medicine and Rehabilitation
Balance, Gait, and Falls Prevention
article

Assessment of reliability and concurrent validity of a single trunk-based IMU system to quantify spatiotemporal parameters in healthy individuals

Bernhard Dumphart, Dieter H. Pahr, U. Ernst, Andrea Zauner-Dungl, Brian Horsak, Simon Zamberger, Lena Wurzinger
article en

Abstract

Commercially available Inertial Measurement Units (IMU) are gaining popularity in clinical gait analysis. Compared to standard optoelectronic motion capture systems (OMCs), IMUs offer advantages such as lower cost, greater time efficiency, and the ability to be used outside of laboratory settings. IMUs can be attached to various body parts and have already been tested in numerous clinical studies. This study aimed to assess the intra-session reliability and concurrent validity of a trunk-based IMU system (BTS G-Walk®) in healthy individuals compared to an OMC system (VICON®). To test the intra-session reliability and concurrent validity of the BTS-G-Walk®, 27 healthy participants were recruited for gait analysis. Both the IMU and OMC systems were used simultaneously to record spatiotemporal gait parameters under a standardized laboratory protocol. Eight spatiotemporal parameters were analyzed, using the Intraclass Correlation Coefficient (ICC 2,k) and Bland–Altman analysis to evaluate the reliability and concurrent validity. The IMU demonstrated excellent intra-session reliability across all parameters (ICC: 0.952–0.995). Concurrent validity was good to excellent for cadence, speed, stride length, and stride duration (ICC: 0.807–0.999), but poor for stance phase, single support, double support, and swing phase (ICC: 0.036–0.136). Bland–Altman analysis showed the lowest mean percentage bias for cadence (− 0.18%) and the highest for double support phase (23.45%). The BTS-G-Walk® delivers reliable values in healthy individuals. Regarding concurrent validity, stride duration and cadence demonstrated the highest agreement with the reference system. Caution is advised when using the IMU in clinical practice, particularly for interpreting parameters dependent on toe-off events, such as gait phase durations.

BMC Sports Science Medicine and RehabilitationVol. 17(1)
University of Applied Sciences St Pölten (AT), Universitätsklinikum Krems (AT), Karl Landsteiner University of Health Sciences (AT)
Karl Landsteiner Privatuniversität für Gesundheitswissenschaften
Openalex Percentile: Top 46%
Balance, Gait, and Falls Prevention
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.