Comparison study of LANJA, UE, and VDO video laryngoscopes for simulated endotracheal intubation in beginners

The emergence of videolaryngoscopy has transformed airway management, being widely adopted for tracheal intubation, and enhancing glottic visualization, especially in complex scenarios. Continuous research is crucial to evaluate the efficacy of various designs. This study aims at evaluating the usability and safety of videolaryngoscopes in novice intubation simulations. This study compares the impact of LANJA, UE, and VDO video laryngoscopes on simulated endotracheal intubation by beginners. This non-randomized concurrent controlled simulation study involved 29 medical student volunteers with no prior endotracheal intubation experience. Following theoretical training by experienced anesthesiologists, participants watched intubation demonstration videos and engaged in hands-on practice. Using LANJA, UE, and VDO video laryngoscopes in random order, participants performed endotracheal intubation on a simulated airway mannequin. Observers recorded intubation procedure videos, analyzing intubation time, success rate, and laryngoscope exposure grading. Significant differences were observed in the time required for glottic exposure with the 3 laryngoscopes (intubation visualization time; LANJA: 5.47 ± 2.84; UE: 9.29 ± 2.88; VDO: 8.97 ± 2.99, P = .001). The endotracheal tube placement time (visualization and fixation time) did not differ significantly among the laryngoscopes (LANJA: 25.21 ± 7.35; UE: 25.04 ± 7.75; VDO: 27.66 ± 3.80, P = .31). Overall intubation success rates varied significantly among the 3 laryngoscopes (LANJA: 89.5%, UE: 78.9%, VDO: 63.2%, P = .002); within Cormack-Lehane grades, LANJA showed the highest percentage in Grade I (68.8%). LANJA video laryngoscope demonstrated a higher success rate in guiding endotracheal intubation, reducing glottic exposure time, and is suitable for use by beginners.

Authors

Institutions

Publication Details

Journal
Medicine
Published
2025-11-21
DOI
https://doi.org/10.1097/md.0000000000045803
Primary Topic
Airway Management and Intubation Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison study of LANJA, UE, and VDO video laryngoscopes for simulated endotracheal intubation in beginners

He Li, Wenqing Ruan, Jian Wang, Wei Yuan et al.
Medicine
Airway Management and Intubation Techniques
article

Comparison study of LANJA, UE, and VDO video laryngoscopes for simulated endotracheal intubation in beginners

He Li, Wenqing Ruan, Jian Wang, Wei Yuan, Mengying Wang, Jiangang Song
article en

Abstract

The emergence of videolaryngoscopy has transformed airway management, being widely adopted for tracheal intubation, and enhancing glottic visualization, especially in complex scenarios. Continuous research is crucial to evaluate the efficacy of various designs. This study aims at evaluating the usability and safety of videolaryngoscopes in novice intubation simulations. This study compares the impact of LANJA, UE, and VDO video laryngoscopes on simulated endotracheal intubation by beginners. This non-randomized concurrent controlled simulation study involved 29 medical student volunteers with no prior endotracheal intubation experience. Following theoretical training by experienced anesthesiologists, participants watched intubation demonstration videos and engaged in hands-on practice. Using LANJA, UE, and VDO video laryngoscopes in random order, participants performed endotracheal intubation on a simulated airway mannequin. Observers recorded intubation procedure videos, analyzing intubation time, success rate, and laryngoscope exposure grading. Significant differences were observed in the time required for glottic exposure with the 3 laryngoscopes (intubation visualization time; LANJA: 5.47 ± 2.84; UE: 9.29 ± 2.88; VDO: 8.97 ± 2.99, P = .001). The endotracheal tube placement time (visualization and fixation time) did not differ significantly among the laryngoscopes (LANJA: 25.21 ± 7.35; UE: 25.04 ± 7.75; VDO: 27.66 ± 3.80, P = .31). Overall intubation success rates varied significantly among the 3 laryngoscopes (LANJA: 89.5%, UE: 78.9%, VDO: 63.2%, P = .002); within Cormack-Lehane grades, LANJA showed the highest percentage in Grade I (68.8%). LANJA video laryngoscope demonstrated a higher success rate in guiding endotracheal intubation, reducing glottic exposure time, and is suitable for use by beginners.

MedicineVol. 104(47)
Shanghai University of Traditional Chinese Medicine (CN), Shuguang Hospital (CN)
Openalex Percentile: Top 45%
Airway Management and Intubation Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.