Development and Validation of a HILIC–HPLC Method for the Quantitative Determination of Favipiravir in Tablet Formulations

Objective: A validated Hydrophilic Interaction Liquid Chromatography (HILIC) method was developed for the quantitative determination of Favipiravir. Methods: The chromatographic analysis was performed using a high-performance liquid chromatography (HPLC) system comprising a diode array detector, vacuum pump, column thermostat, and autosampler (Agilent 1260, Agilent Technologies, Santa Clara, CA, USA). The analysis was conducted on a ZORBAX RRHD HILIC Plus analytical column (95 Å, 2.1 × 150 mm, 1.8 µm). The mobile phase consisted of acetonitrile and water (80:20, v/v). Chromatographic separation was achieved under isocratic elution at a flow rate of 0.8 mL/min, and Favipiravir was detected at a wavelength of 322 nm. Results: The retention time of Favipiravir was 1.8317 ± 0.002 min, with a limit of detection (LOD) of 0.14 μg/mL and a limit of quantification (LOQ) of 0.47 μg/mL. The regression equation was y = 107.54x + 17.034 with a correlation coefficient (r²) of 0.9997. Conclusion: The proposed method was validated in terms of specificity, linearity, accuracy, precision, LOD, and LOQ, and was successfully applied for the quantitative analysis of Favipiravir in tablet formulations.

Authors

Institutions

Publication Details

Journal
Pharmata
Published
2025-11-26
DOI
https://doi.org/10.62425/pharmata.1759097
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Validation of a HILIC–HPLC Method for the Quantitative Determination of Favipiravir in Tablet Formulations

Dilhe Nur Çim
Pharmata
Analytical Chemistry and Chromatography
article

Development and Validation of a HILIC–HPLC Method for the Quantitative Determination of Favipiravir in Tablet Formulations

Dilhe Nur Çim
article en

Abstract

Objective: A validated Hydrophilic Interaction Liquid Chromatography (HILIC) method was developed for the quantitative determination of Favipiravir. Methods: The chromatographic analysis was performed using a high-performance liquid chromatography (HPLC) system comprising a diode array detector, vacuum pump, column thermostat, and autosampler (Agilent 1260, Agilent Technologies, Santa Clara, CA, USA). The analysis was conducted on a ZORBAX RRHD HILIC Plus analytical column (95 Å, 2.1 × 150 mm, 1.8 µm). The mobile phase consisted of acetonitrile and water (80:20, v/v). Chromatographic separation was achieved under isocratic elution at a flow rate of 0.8 mL/min, and Favipiravir was detected at a wavelength of 322 nm. Results: The retention time of Favipiravir was 1.8317 ± 0.002 min, with a limit of detection (LOD) of 0.14 μg/mL and a limit of quantification (LOQ) of 0.47 μg/mL. The regression equation was y = 107.54x + 17.034 with a correlation coefficient (r²) of 0.9997. Conclusion: The proposed method was validated in terms of specificity, linearity, accuracy, precision, LOD, and LOQ, and was successfully applied for the quantitative analysis of Favipiravir in tablet formulations.

PharmataVol. 5(3)
Trakya University (TR)
Openalex Percentile: Top 67%
Analytical Chemistry and Chromatography
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.