Integrated desiccant-coated heat pump for air conditioning and battery thermal management in electric buses

With the growing demand for electric vehicles, improving battery stability and enhancing the energy efficiency of air conditioning (AC) systems have become increasingly important. This study introduces a desiccant coated heat pump (DCHP) system integrated with an AC unit and a battery thermal management system (BTMS) for electric buses. The proposed system directly coats desiccant on the evaporator and condenser surfaces, allowing independent temperature and humidity control. Numerical analyses validated by experiments demonstrated significant improvements in thermal performance. Under summer conditions, the system achieved a cooling coefficient of performance ( ) of 5.92, representing a 110% improvement over the conventional system, while providing a moisture removal capacity (MRC) of 10.8 g/kg without requiring a reheating process. In winter, the heating COP ( ) reached 8.9, representing a 134% improvement, with a moisture supply capacity (MSC) of 3.6 g/kg, thus maintaining humidity under dry ambient conditions. A parametric study highlighted the sensitivity of system performance to air velocity, half-cycle time, and evaporation/condensation temperatures, identifying optimal operating ranges for practical applications. The system maintained cell temperatures below 47 °C under extreme heat and achieved uniform preheating to 0 °C within 727s under extreme cold for battery management. These results confirm that the DCHP-based integrated system simultaneously ensures cabin comfort and battery stability, while reducing energy consumption compared to conventional approaches. The findings provide a foundation for advancing high-efficiency, multifunctional thermal management solutions in electric buses, supporting extended driving range, enhanced passenger comfort, and improved reliability in diverse climates.

Authors

Institutions

Publication Details

Journal
Case Studies in Thermal Engineering
Published
2025-11-24
DOI
https://doi.org/10.1016/j.csite.2025.107451
Primary Topic
Adsorption and Cooling Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integrated desiccant-coated heat pump for air conditioning and battery thermal management in electric buses

Hwa Yeong Lee, Peyman Gholamali Zadeh, Mahdi Koushaeian, Joshua C. Pack et al.
Case Studies in Thermal Engineering
Adsorption and Cooling Systems
article

Integrated desiccant-coated heat pump for air conditioning and battery thermal management in electric buses

Hwa Yeong Lee, Peyman Gholamali Zadeh, Mahdi Koushaeian, Joshua C. Pack, Joanne T. Chang, Kyung Jin Bae, Oh Kyung Kwon, Jun Yang Jeong, Chan Hee Han, Jae Dong Chung
article en

Abstract

With the growing demand for electric vehicles, improving battery stability and enhancing the energy efficiency of air conditioning (AC) systems have become increasingly important. This study introduces a desiccant coated heat pump (DCHP) system integrated with an AC unit and a battery thermal management system (BTMS) for electric buses. The proposed system directly coats desiccant on the evaporator and condenser surfaces, allowing independent temperature and humidity control. Numerical analyses validated by experiments demonstrated significant improvements in thermal performance. Under summer conditions, the system achieved a cooling coefficient of performance ( ) of 5.92, representing a 110% improvement over the conventional system, while providing a moisture removal capacity (MRC) of 10.8 g/kg without requiring a reheating process. In winter, the heating COP ( ) reached 8.9, representing a 134% improvement, with a moisture supply capacity (MSC) of 3.6 g/kg, thus maintaining humidity under dry ambient conditions. A parametric study highlighted the sensitivity of system performance to air velocity, half-cycle time, and evaporation/condensation temperatures, identifying optimal operating ranges for practical applications. The system maintained cell temperatures below 47 °C under extreme heat and achieved uniform preheating to 0 °C within 727s under extreme cold for battery management. These results confirm that the DCHP-based integrated system simultaneously ensures cabin comfort and battery stability, while reducing energy consumption compared to conventional approaches. The findings provide a foundation for advancing high-efficiency, multifunctional thermal management solutions in electric buses, supporting extended driving range, enhanced passenger comfort, and improved reliability in diverse climates.

Case Studies in Thermal EngineeringVol. 76
Sejong University (KR), Korean Society for Digital Policy (KR), Korea Institute of Industrial Technology (KR)
Openalex Percentile: Top 62%
Adsorption and Cooling Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.