Dosimetric characterization of a <sup>90</sup> Sr <sup>90</sup> Y Pterygium applicator with radiochromic film and Monte Carlo Simulations

<i>Objective</i>.<i>β</i>-emitting radionuclides, such as<sup>90</sup>Sr<sup>90</sup>Y, are widely used in clinical settings for the treatment of both benign and malignant lesions, particularly as surface applicators. Despite their clinical relevance, the three-dimensional dose distributions delivered by these applicators remain inadequately characterized using Monte Carlo simulations, the current gold standard for dose calculation. This study aims to address these limitations by characterizing the three-dimensional dose distribution of a commonly used<sup>90</sup>Sr<sup>90</sup>Y Pterygium applicator. The goals include generating accurate percent-depth-dose (PDD) curves and validating a custom irradiation setup using radiochromic film and Monte Carlo simulations to enable accessible, reproducible, and highly precise radiobiology experiments.<i>Approach</i>. A Monte Carlo dose calculation software based on Geant4 10.02.p02 was developed, and the Amersham SIA 20 Pterygium applicator, a stacked film setup with 30 EBT-XD GafChromic<sup>®</sup>films, and a film-cell irradiation setup (a film layer, cell monolayer, and growth media) were modeled. The dose rate was averaged over the 8.2 mm diameter active area on the surface in water in both the stacked film setup and the film-cell setup. The spectrum of the source was also calculated. An experimental PDD was generated by irradiating stacked films and was compared to the Monte Carlo simulations.<i>Main results</i>. The measured and computed PDDs agreed within 2% within 2.6 mm of depth. The dose rates were 28.30, 26.48, 21.23, and 22.76 cGy s<sup>-1</sup>on the surface in water, in the film active layer, in the cell monolayer, and in the growth media, respectively, compared to the manufacturer's nominal value of 27 cGy s<sup>-1</sup>.<i>Significance</i>. A Monte Carlo-validated PDD curve of the source was generated in a stacked film setup using EBT-XD GafChromic<sup>®</sup>film. A custom film-cell irradiation setup was characterized for future radiobiology experiments.

Authors

Institutions

Publication Details

Journal
Physics in Medicine and Biology
Published
2025-11-26
DOI
https://doi.org/10.1088/1361-6560/ae24dc
Primary Topic
Corneal Surgery and Treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dosimetric characterization of a 90 Sr 90 Y Pterygium applicator with radiochromic film and Monte Carlo Simulations

Shirin Abbasinejad Enger, Parminder S. Basran, Maryam Rahbaran
Physics in Medicine and Biology
Corneal Surgery and Treatments
article

Dosimetric characterization of a 90 Sr 90 Y Pterygium applicator with radiochromic film and Monte Carlo Simulations

Shirin Abbasinejad Enger, Parminder S. Basran, Maryam Rahbaran
article en

Abstract

<i>Objective</i>.<i>β</i>-emitting radionuclides, such as<sup>90</sup>Sr<sup>90</sup>Y, are widely used in clinical settings for the treatment of both benign and malignant lesions, particularly as surface applicators. Despite their clinical relevance, the three-dimensional dose distributions delivered by these applicators remain inadequately characterized using Monte Carlo simulations, the current gold standard for dose calculation. This study aims to address these limitations by characterizing the three-dimensional dose distribution of a commonly used<sup>90</sup>Sr<sup>90</sup>Y Pterygium applicator. The goals include generating accurate percent-depth-dose (PDD) curves and validating a custom irradiation setup using radiochromic film and Monte Carlo simulations to enable accessible, reproducible, and highly precise radiobiology experiments.<i>Approach</i>. A Monte Carlo dose calculation software based on Geant4 10.02.p02 was developed, and the Amersham SIA 20 Pterygium applicator, a stacked film setup with 30 EBT-XD GafChromic<sup>®</sup>films, and a film-cell irradiation setup (a film layer, cell monolayer, and growth media) were modeled. The dose rate was averaged over the 8.2 mm diameter active area on the surface in water in both the stacked film setup and the film-cell setup. The spectrum of the source was also calculated. An experimental PDD was generated by irradiating stacked films and was compared to the Monte Carlo simulations.<i>Main results</i>. The measured and computed PDDs agreed within 2% within 2.6 mm of depth. The dose rates were 28.30, 26.48, 21.23, and 22.76 cGy s<sup>-1</sup>on the surface in water, in the film active layer, in the cell monolayer, and in the growth media, respectively, compared to the manufacturer's nominal value of 27 cGy s<sup>-1</sup>.<i>Significance</i>. A Monte Carlo-validated PDD curve of the source was generated in a stacked film setup using EBT-XD GafChromic<sup>®</sup>film. A custom film-cell irradiation setup was characterized for future radiobiology experiments.

Physics in Medicine and BiologyVol. 70(24)
Cornell University (US), McGill University Health Centre (CA), Jewish General Hospital (CA), McGill University (CA)
Openalex Percentile: Top 49%
Corneal Surgery and Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.